Proximally Coated Ingrowth Prostheses
- 1 November 1997
- journal article
- review article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 344, 139???149
- https://doi.org/10.1097/00003086-199711000-00015
Abstract
Proximally coated femoral components for cementless total hip replacement were conceived in the early 1980s in response to the proximal stress shielding that was seen with extensively coated devices. The main purpose of this study was to analyze whether these prostheses remain viable options based on the results of presently used devices, while detailing the problems encountered with first generation devices. The evolution of these designs and how they were modified in response to early problems, was reviewed. Initial iterations were less successful because they were sometimes not stable, had problems with thigh pain, and progressive osteolysis. However, second generation devices with greater than 5 years clinical experience seem promising and have shown very low aseptic loosening rates (1%-3%), and less thigh pain (under 5% in most studies). The reader still must await longer term studies to know whether progressive osteolysis will be a problem. These encouraging midterm results can be attributed to improved geometry, instruments, and technique which ensure initial implant stability. Proximal coating must be circumferential, to seal the diaphysis from wear debris. After incorporating design changes in response to the significant failures of early devices, the concept of proximal coating for cementless femoral stems seems viable, as long as the twin requirements of circumferential coating and rigid initial stability are realized.Keywords
This publication has 29 references indexed in Scilit:
- Clinical and radiographic outcome of a cementless, titanium, plasma spray-coated total hip arthroplasty femoral componentThe Journal of Arthroplasty, 1996
- Comparative results of a distal modular sleeve, circumferential coating, and stiffness relief using the Anatomic Porous Replacement IIThe Journal of Arthroplasty, 1996
- The Wisconsin noncemented femoral stem: A prospective study with 5 to 9 years of follow-up evaluationThe Journal of Arthroplasty, 1995
- Taperloc femoral component: A 2–6-year study of the first 100 consecutive casesThe Journal of Arthroplasty, 1994
- Effects of porous coating, with and without collar support, on early relative motion for a cementless hip prosthesisJournal of Biomechanics, 1993
- The porous-coated anatomic total hip prosthesis, inserted without cement. Results after five to seven years in a prospective study.Journal of Bone and Joint Surgery, 1993
- A prospective study of 100 consecutive harris-galante porous total hip arthroplasties: 2–5—Year resultsThe Journal of Arthroplasty, 1992
- Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space.Journal of Bone and Joint Surgery, 1992
- Tissue growth into porous primary and revision femoral stemsThe Journal of Arthroplasty, 1991
- The Optimum Pore Size for the Fixation of Porous-Surfaced Metal Implants by the Ingrowth of BoneClinical Orthopaedics and Related Research, 1980