The intrinsic signal‐to‐noise ratio in NMR imaging
- 1 August 1986
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 3 (4) , 604-618
- https://doi.org/10.1002/mrm.1910030413
Abstract
The fundamental limit for NMR imaging is set by an intrinsic signal-to-noise ratio (SNR) for a particular combination of rf antenna and imaging subjects. The intrinsic SNR is the signal from a small volume of material in the sample competing with electrical noise from thermally generated, random noise currents in the sample. The intrinsic SNR has been measured for a number of antenna-body section combinations at several different values of the static magnetic field and is proportional to B0. We have applied the intrinsic and system SNR to predict image SNR and have found satisfactory agreement with measurements on images. The relationship between SNR and pixel size is quite different in NMR than it is with imaging modalities using ionizing radiation, and indicates that the initial choice of pixel size is crucial in NMR. The analog of "contrast-detail-dose" plots for ionizing radiation imaging modalities is the "contrast-detail-time" plot in NMR, which should prove useful in choosing a suitable pixel array to visualize a particular anatomical detail for a given NMR receiving antenna.Keywords
This publication has 9 references indexed in Scilit:
- Calculated T1 images derived from a partial saturation-inversion recovery pulse sequence with adiabatic fast passageMagnetic Resonance Imaging, 1985
- A review of normal tissue hydrogen NMR relaxation times and relaxation mechanisms from 1–100 MHz: Dependence on tissue type, NMR frequency, temperature, species, excision, and ageMedical Physics, 1984
- A signal-to-noise calibration procedure for NMR imaging systemsMedical Physics, 1984
- Signal, Noise, and Contrast in Nuclear Magnetic Resonance (NMR) ImagingJournal of Computer Assisted Tomography, 1983
- Spin warp NMR imaging and applications to human whole-body imagingPhysics in Medicine & Biology, 1980
- The sensitivity of the zeugmatographic experiment involving human samplesJournal of Magnetic Resonance (1969), 1979
- The Use of Contrast-Detail-Dose Evaluation of Image Quality in a Computed Tomographic ScannerJournal of Computer Assisted Tomography, 1979
- NMR Fourier zeugmatographyJournal of Magnetic Resonance (1969), 1975
- The Sensitivity Performance of the Human Eye on an Absolute Scale*Journal of the Optical Society of America, 1948