Ion suppression in the determination of clenbuterol in urine by solid‐phase extraction atmospheric pressure chemical ionisation ion‐trap mass spectrometry
- 30 December 2002
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 17 (3) , 245-250
- https://doi.org/10.1002/rcm.908
Abstract
Ion suppression effects were observed during the determination of clenbuterol in urine with solid-phase extraction/multiple-stage ion-trap mass spectrometry (SPE/MS3), despite the use of atmospheric pressure chemical ionisation. During SPE, a polymeric stationary phase (polydivinylbenzene) was applied. Post-cartridge infusion of analyte to the SPE eluate after the extraction of blank urine was performed to obtain a profile of the suppression. Single and multiple-stage MS were performed to provide insight in the suppressing compounds. The ion suppression was mainly ascribed to two m/z values, but still no identification of the compounds was achieved from the multiple-stage MS data. No ionisable and non-ionisable complexes and/or precipitation of clenbuterol with matrix compounds were observed. A concentration dependence of the percentage of suppression was observed. Up to 70% of the signal was suppressed upon post-cartridge infusion of 0.22 μg/mL (at 5 μL/min) clenbuterol into the eluate, and this decreased to about 4% at infusion of 22 μg/mL clenbuterol. Molecularly imprinted polymers were used to enhance the selectivity of the extraction. Although matrix components were still present after extraction, no interference of these compounds with the analyte was observed. However, the bleeding of the imprint from the polymer (brombuterol) caused significant ion suppression. Copyright © 2002 John Wiley & Sons, Ltd.Keywords
This publication has 37 references indexed in Scilit:
- Improvement in precision of the liquid chromatographic–electrospray ionization tandem mass spectrometric analysis of 3′-C-ethynylcytidine in rat plasmaJournal of Chromatography B: Biomedical Sciences and Applications, 2001
- Exploring the boundaries of bioanalytical quantitative LC–MS–MSTrAC Trends in Analytical Chemistry, 2000
- On-line coupling of solid-phase extraction with mass spectrometry for the analysis of biological samples: I. Determination of clenbuterol in urineJournal of Chromatography A, 1999
- Postcolumn Introduction of an Internal Standard for Quantitative LC−MS AnalysisAnalytical Chemistry, 1999
- Multiple-Stage Tandem Mass Spectrometry for Structural Characterization of SaponinsAnalytical Chemistry, 1998
- Rapid target analysis of microcontaminants in water by on-line single-short-column liquid chromatography combined with atmospheric pressure chemical ionization ion-trap mass spectrometryJournal of Chromatography A, 1998
- Mechanistic aspects of electrospray ionizationJournal of Chromatography A, 1998
- Rapid target analysis of microcontaminants in water by on-line single-short-column liquid chromatography combined with atmospheric pressure chemical ionization tandem mass spectrometryJournal of Chromatography A, 1997
- Comparison of high- and low-energy collision-induced dissociation tandem mass spectrometry in the analysis of glycoalkaloids and their aglyconsJournal of the American Society for Mass Spectrometry, 1996
- Ion spray interface for combined liquid chromatography/atmospheric pressure ionization mass spectrometryAnalytical Chemistry, 1987