Simultaneous Determination of Cross-Reactive Leukotrienes in Biological Matrices Using On-line Liquid Chromatography Immunochemical Detection
- 1 December 1996
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 68 (23) , 4101-4106
- https://doi.org/10.1021/ac960250r
Abstract
Sulfidopeptide leukotrienes, which are important biomarkers for several diseases, are commonly measured by microtiter plate immunoassays. These immunoassays, however, cannot distinguish between several structurally similar leukotrienes and their cross-reactive metabolites and, therefore, need extensive sample handling and fractionation by means of liquid chromatography (LC). This paper describes the development and automation of a continuous-flow immunochemical detection (ICD) system and its subsequent on-line coupling to LC. The on-line LC-ICD system based on fluorescence-labeled leukotriene E4 (LTE4) was used to determine sulfidopeptide leukotrienes and their cross-reactive metabolites in a single run. Furthermore, biological matrices, e.g., urine and human cell extracts, were analyzed, the only sample pretreatment being on-line solid-phase extraction (SPE) on a novel RP-C4 restricted-access support. The determination limit of LTE4 in urine was 0.2 ng/mL (800 fmol; injection volume, 2000 μL; signal-to-noise ratio, 10). The system was linear from 0.2 to 1.0 ng/mL LTE4. Using nonlinear curve-fitting, the range could be expanded to 2.5 ng/mL. It is shown that, besides quantitation of known analytes, on-line LC-ICD is useful in the discovery of cross-reactive LTE4 metabolites.Keywords
This publication has 10 references indexed in Scilit:
- Online Coupling of Liquid Chromatography to Biochemical Assays Based on Fluorescent-Labeled LigandsAnalytical Chemistry, 1994
- Simultaneous determination of leukotrienes B4 and E4 in whole blood and of leukotriene E4 in urine of rabbit by reversed-phase high-performance liquid chromatographyJournal of Chromatography B: Biomedical Sciences and Applications, 1994
- An improved assay for urinary LTE4Prostaglandins, 1994
- Bioanalysis of digoxin and its metabolites using direct serum injection combined with liquid chromatography and on-line immunochemical detectionJournal of Chromatography B: Biomedical Sciences and Applications, 1994
- On-line immunochemical detection in liquid chromatography using fluorescein-labelled antibodiesJournal of Chromatography A, 1993
- Inhibition of leukotriene ω-oxidation by ω-trifluoro analogs of leukotrienesArchives of Biochemistry and Biophysics, 1990
- Metabolism of cysteinyl leukotrienes in monkey and manEuropean Journal of Biochemistry, 1990
- BIO-fully automated sample treatment high-performance liquid chromatography and radioimmunoassay for leukotriene E4 in human urine from asthmaticsJournal of Chromatography B: Biomedical Sciences and Applications, 1990
- Modern high-performance liquid chromatographic-radioimmunoassay strategies for the study of eicosanoids in biological samplesJournal of Chromatography B: Biomedical Sciences and Applications, 1989
- Leukotrienes and Lipoxins: Structures, Biosynthesis, and Biological EffectsScience, 1987