Case Report: Symptomatic Port-Site Hernia Associated with a Non-Bladed Trocar after Laparoscopic Live-Donor Nephrectomy
- 1 September 2003
- journal article
- case report
- Published by Mary Ann Liebert Inc in Journal of Endourology
- Vol. 17 (7) , 493-494
- https://doi.org/10.1089/089277903769013649
Abstract
We describe what appears to be the first case of a port-site hernia at the site of insertion of a 10-mm non-bladed trocar, which was discovered 4 days after laparoscopic live-donor nephrectomy. We now close all 10-mm port sites in adults and all 5-mm port sites in children; this can be done easily using the Carter-Thomason device.Keywords
This publication has 2 references indexed in Scilit:
- Laparoscopic Radical NephrectomyJournal of Urology, 2002