Measurement of Regional Cerebral Blood Flow with Positron Emission Tomography: A Comparison of [15O]Water to [11C]Butanol with Distributed-Parameter and Compartmental Models
Open Access
- 1 September 1993
- journal article
- research article
- Published by SAGE Publications in Journal of Cerebral Blood Flow & Metabolism
- Vol. 13 (5) , 733-747
- https://doi.org/10.1038/jcbfm.1993.94
Abstract
To further our understanding of the best way to measure regional CBF with positron emission tomography (PET), we directly compared two candidate tracers ([15O]water and [11C]butanol, administered intravenously) and two popular implementations of the one-compartment (IC) model: the autoradiographic implementation representing a single PET measurement of tissue radioactivity over 1 min and a dynamic implementation representing a sequence of measurements of tissue radioactivity over 200 s. We also examined the feasibility of implementing a more realistic, and thus more complex, distributed-parameter (DP) model by assigning fixed values for all of its parameters other than CBF and tracer volume of distribution ( Vd), a requirement imposed by the low temporal resolution and statistical quality of PET data. The studies were performed in three normal adult human subjects during paired rest and visual stimulation. In each subject seven regions of interest (ROIs) were selected, one of which was the primary visual cortex. The corresponding ROI were anatomically equivalent in the three subjects. Regional CBF, Vd, tracer arrival delay, and dispersion were estimated for the dynamic data curves. A total of 252 parameter sets were estimated. With [11C]butanol both implementations of the IC model provided similar results ( r = 0.97). Flows estimated using the 1C models were lower (p < 0.01) with [15O]water than with [11C]butanol. In comparison with the IC model, the constrained version of the DP used in these studies performed inadequately, overestimating high flow and underestimating low flow with both tracers, possibly as the result of the necessity of assigning fixed values for all of its parameters other than CBF and Vd.Keywords
This publication has 43 references indexed in Scilit:
- Measurement of Human Cerebral Blood Flow with [15O]Butanol and Positron Emission TomographyJournal of Cerebral Blood Flow & Metabolism, 1991
- Retinotopic organization of human visual cortex mapped with positron- emission tomographyJournal of Neuroscience, 1987
- Weighted Integration Method for Local Cerebral Blood Flow Measurements with Positron Emission TomographyJournal of Cerebral Blood Flow & Metabolism, 1986
- A comparison between regional cerebral blood flow measurements obtained in human subjects using11C-methylalbumin microspheres, the C15O2steady-state method, and positron emission tomographyActa Neurologica Scandinavica, 1986
- A Stereotactic Method of Anatomical Localization for Positron Emission TomographyJournal of Computer Assisted Tomography, 1985
- Strategy for the Measurement of Regional Cerebral Blood Flow Using Short-Lived Tracers and Emission TomographyJournal of Cerebral Blood Flow & Metabolism, 1984
- Quantitative Measurement of Regional Cerebral Blood Flow and Oxygen Metabolism in Man Using 15O and Positron Emission TomographyJournal of Computer Assisted Tomography, 1980
- The Diffusion Permeability to Water of the Rat Blood‐Brain BarrierActa Physiologica Scandinavica, 1975
- Evidence of the Limitations of Water as a Freely Diffusible Tracer in Brain of the Rhesus MonkeyCirculation Research, 1974
- Regional Cerebral Blood Flow in the Rat Measured by the Tissue Sampling Technique; a Critical Evaluation Using Four Indicators C14‐Antipyrine, C14‐Ethanol H3‐Water and Xenon133Acta Physiologica Scandinavica, 1974