Long‐Term Internal Cardiac Defibrillation Threshold Stability
- 1 March 1989
- journal article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 12 (3) , 443-450
- https://doi.org/10.1111/j.1540-8159.1989.tb02682.x
Abstract
The automatic implantable cardioverter‐defibrillator is tested intraoperatively with defibrillation trials to ensure effectiveness. It is unknown if the energy requirement for internal defibrillation remains stable and that once demonstrated effective, if the device will continue to be effective in terminating lethal ventricular arrhythmias. In this study, the defibrillation energy requirement was compared in 56 patients at the time of lead implantation to that obtained at the time of generator replacement. Mean time to generator replacement was 17. ± 6.6 months. The defibrillation threshold was stable over that time (11. 9 ± 6.7 joules compared to 12.7 ± 8.4 joules, NS). There was no relation between transmyocardial impedance and defibrillation threshold. In addition, no effect on defibrillation threshold was demonstrated by the use of various cardiac medications, concomitant surgery or the occurrence of clinical shocks during follow‐up.Keywords
This publication has 17 references indexed in Scilit:
- Success of chronic defibrillation and the role of antiarrhythmic drugs with the automatic implantable cardioverter/defibrillatorThe American Journal of Cardiology, 1987
- The relationship between successful defibrillation and delivered energy in open-chest dogs: Reappraisal of the “defibrillation threshold” conceptAmerican Heart Journal, 1987
- The Characterization of Human Transmyocardial Impedance during Implantation of the Automatic Internal Cardioverter DefibrillatorPacing and Clinical Electrophysiology, 1986
- Clinical experience, complications, and survival in 70 patients with the automatic implantable cardioverter/defibrillator.Circulation, 1985
- Automated impedance-based energy adjustment for defibrillation: experimental studies.Circulation, 1985
- Practical aspects of automatic cardioverter/defibrillator implantationAmerican Heart Journal, 1984
- Cardiac damage in dogs with chronically implanted automatic defibrillator electrode catheters and given four episodes of multiple shocksAmerican Heart Journal, 1983
- The effect of newer antiarrhythmic drugs on defibrillation thresholdCritical Care Medicine, 1980
- Elevation of ventricular defibrillation threshold in dogs by antiarrhythmic drugsAmerican Heart Journal, 1979
- Cardiac pacing and pacemakers IV. Threshold of cardiac stimulationAmerican Heart Journal, 1977