The Effect of Full Protective Gear on Intubation Performance by Hospital Medical Personnel
Open Access
- 1 April 2000
- journal article
- research article
- Published by Oxford University Press (OUP) in Military Medicine
- Vol. 165 (4) , 272-274
- https://doi.org/10.1093/milmed/165.4.272
Abstract
Objective: To assess the influence of protective gear on intubation performance. Design: Prospective, controlled measurement of duration and quality of intubations performed on mannequins by medical personnel with and without protective gear in a crossover design. Participants: Eight teams each comprising an anesthesiologist and a nurse. Results: Intubation duration with and without chemical warfare gear was 69.2 ± 7 and 47.3 ± 6 seconds (mean ± SEM), respectively (p < 0.05). Moreover, rating of intubation quality as “very good” by the anesthesiologists declined significantly from 62.5% without chemical warfare protective gear to 6.25% with the garment and mask. Tube fixation was the rate-limiting step when performed with protective gear (p < 0.05); it was assessed by 81% of the anesthesiologists as the critical step. A learning curve was not observed during the study. Conclusion: Protective gear causes a significant prolongation of intubation duration; however, endotracheal intubation can be performed effectively. Technical improvements are warranted for tube fixation because it is the critical step.Keywords
This publication has 0 references indexed in Scilit: