13N ammonia myocardial imaging at rest and with exercise in normal volunteers. Quantification of absolute myocardial perfusion with dynamic positron emission tomography.
- 1 November 1989
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 80 (5) , 1328-1337
- https://doi.org/10.1161/01.cir.80.5.1328
Abstract
Positron emission tomography (PET) was applied to the measurement of myocardial perfusion using the perfusion tracer 13N-labeled ammonia. 13N ammonia was delivered intravenously to 13 healthy volunteers both at rest and during supine bicycle exercise. Dynamic PET imaging was obtained in three cross-sectional planes for 10 minutes commencing with each injection. The left ventricle was divided into eight sectors, and a small region of interest was assigned to the left ventricular blood pool to obtain the arterial input function. The net extraction of 13N ammonia was obtained for each sector by dividing the tissue 13N concentration at 10 minutes by the integral of the input function from the time of injection to 10 minutes. With this approach for calculating net extractions, rest and exercise net extractions were not significantly different from each other. To obviate possible overestimation of the true 13N ammonia input function by contamination by 13N-labeled compounds other than 13N ammonia or by spillover from myocardium into blood pool, the net extractions were calculated using only the first 90 seconds of the blood and tissue time-activity curves. This approach for calculating net extractions yielded significant differences between rest and exercise, with an average ratio of exercise to rest of 1.38 +/- 0.34. Nonetheless, the increase was less than predicted from the average 2.7-2.8-fold increase in double product at peak exercise or the 1.7-fold increase in double product at 1 minute after exercise. However, when the first 90 seconds of dynamic data were fit with a two compartment tracer kinetic model, average perfusion rates of 0.75 +/- 0.43 ml/min/g at rest and 1.50 +/- 0.74 ml/min/g with exercise were obtained. This average increase in perfusion of 2.2-fold corresponded to similar average increases in double product. Thus, the noninvasive technique of PET imaging with 13N ammonia shows promise for future applications in determining absolute flows in patients with coronary artery disease.This publication has 39 references indexed in Scilit:
- Validation in dogs of a rapid digital angiographic technique to measure relative coronary blood flow during routine cardiac catheterizationThe American Journal of Cardiology, 1985
- Quantification of regional myocardial blood flow in vivo with H215O.Circulation, 1984
- Relation between regional myocardial uptake of rubidium-82 and perfusion: Absolute reduction of cation uptake in ischemiaThe American Journal of Cardiology, 1982
- Noninvasive assessment of coronary stenoses by myocardial imaging during pharmacologic coronary vasodilationThe American Journal of Cardiology, 1982
- Intravenous dipyridamole combined with isometric handgrip for near maximal acute increase in coronary flow in patients with coronary artery diseaseThe American Journal of Cardiology, 1981
- Regional myocardial blood flow, metabolism and function assessed noninvasively with positron emission tomographyThe American Journal of Cardiology, 1980
- The dependence of accumulation of 13NH3 by myocardium on metabolic factors and its implications for quantitative assessment of perfusion.Circulation, 1980
- Regional myocardial perfusion assessed with N-13 labeled ammonia and positron emission computerized axial tomographyThe American Journal of Cardiology, 1979
- Noninvasive assessment of coronary stenoses with myocardial perfusion imaging during pharmacologic coronary vasodilatationThe American Journal of Cardiology, 1979
- The effect of nitroglycerin on coronary blood flow and the hemodynamic response to exercise in coronary artery diseaseThe American Journal of Cardiology, 1971