Control of Humidity in Small Controlled-environment Chambers using Glycerol-Water Solutions
- 1 January 1992
- journal article
- Published by American Society for Horticultural Science in HortTechnology
- Vol. 2 (1) , 52-54
- https://doi.org/10.21273/horttech.2.1.52
Abstract
Solutions of glycerol and water provide a convenient and inexpensive system to control the relative humidity (RH) in small controlled-environment chambers. The relationship between the specific gravity (SG) of a glycerol-water solution and its equilibrium RH is described by the equation SG = [-0.189 (RH) + 19.9]0.0806. Gas can be humidified by bubbling it through jars containing solutions of glycerol-water with the desired equilibrium RH. The effects of flow rate, volume of solution, temperature, and pressure on the equilibrium RH are discussed.Keywords