Fast T1 mapping with volume coverage
Open Access
- 2 July 2001
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 46 (1) , 131-140
- https://doi.org/10.1002/mrm.1168
Abstract
Four different sequences which enable high-resolution, multislice T1 relaxation-time mapping are presented. All these sequences are based on the Look-Locker method with differences arising from the use of either a saturation-recovery or inversion-recovery module prior to data acquisition with a full k-space or banded k-space acquisition scheme. The methods were implemented on a standard clinical scanner and the accuracy of the T1 results was evaluated against spectroscopic measurements. The accuracy of the T1 maps validated by phantom imaging measurements is around 1% for species which relax with T1 times that mimic gray/white matter (T1 ≤ 1000 ms). Additionally, the inherent multislice, multipoint capability of the methods is demonstrated. Finally, in vivo results of the human brain obtained using the faster method are presented. The fastest data acquisition was achieved with a saturation-recovery, banded k-space method where k-space was divided into three segments; an overall acquisition time of around 5 min (for species with T1 ≤ 1 sec) was achieved for a T1 map which can, in principle, provide whole-brain coverage with a matrix size of 256 × 256 at multiple time-points. Magn Reson Med 46:131–140, 2001.Keywords
This publication has 36 references indexed in Scilit:
- T1 mapping from spin echo and stimulated echoesMedical Physics, 1995
- A novel fast T1‐mapping methodJournal of Magnetic Resonance Imaging, 1994
- Accurate T1 determination from inversion recovery images: Application to human brain at 4 TeslaMagnetic Resonance in Medicine, 1994
- Spin‐lattice relaxation time measurement by means of a TurboFLASH techniqueMagnetic Resonance in Medicine, 1993
- Quantification of regional blood volumes by rapid T1 mappingMagnetic Resonance in Medicine, 1993
- Fast and accurate measurements of T1 using a multi‐readout single inversion‐recovery sequenceMagnetic Resonance in Medicine, 1992
- Quantification of T1 values by SNAPSHOT-FLASH NMR imagingJournal of Magnetic Resonance (1969), 1992
- Practical Implementation and Optimization of One‐shot T1 imagingMagnetic Resonance in Medicine, 1991
- Inversion Recovery Snapshot FLASH MR ImagingJournal of Computer Assisted Tomography, 1989
- A single-scan fourier transform method for measuring spin-lattice relaxation timesJournal of Magnetic Resonance (1969), 1976