X-ray Photoelectron Spectroscopy, Time-of-Flight Secondary Ion Mass Spectrometry, and Principal Component Analysis of the Hydrolysis, Regeneration, and Reactivity of N-Hydroxysuccinimide-Containing Organic Thin Films
- 11 October 2007
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 79 (22) , 8781-8788
- https://doi.org/10.1021/ac0715423
Abstract
N-Hydroxysuccinimide (NHS) esters are widely used as leaving groups to activate covalent coupling of amine-containing biomolecules onto surfaces in academic and commercial surface immobilizations. Their intrinsic hydrolytic instability is well-known and remains a concern for maintaining stable, reactive surface chemistry, especially for reliable longer term storage. In this work, we use X-ray photoelectron spectroscopy and time-of-flight secondary ion mass spectrometry (TOF-SIMS) to investigate surface hydrolysis in NHS-bearing organic thin films. Principal component analysis (PCA) of both positive and negative ion TOF-SIMS data was used to correlate changes in the well-defined NHS ester oligo(ethylene glycol) (NHS-OEG) self-assembled monolayers to their surface treatment. From PCA results, multivariate peak intensity ratios were developed for monitoring NHS reactivity, thin-film thickness, and oxidation of the monolayers during surface hydrolysis. Aging in ambient air for up to 7 days resulted in hydrolysis of some fraction of bound NHS groups, oxidation of some resident thiol groups, and deposition of adventitious hydrocarbon contaminants onto the monolayers. Overnight film immersion under water produced complete hydrolysis and removal of the NHS chemistry, as well as removal of some of the thiolated OEG chains. NHS regeneration of the hydrolyzed surfaces was assessed using the same multivariable peak intensity ratio as well as surface coupling with amine-terminated molecules. Both aqueous and organic NHS regeneration methods produced surfaces with bound NHS concentrations ∼50% of the bound NHS concentration on freshly prepared NHS-OEG monolayers. Precise methods for quantifying NHS chemistry on surfaces are useful for quality control processes required in surface technologies that rely on reliable and reproducible reactive ester coupling. These applications include microarray, microfluidic, immunoassay, bioreactor, tissue engineer-ing, and biomedical device fabrication.Keywords
This publication has 30 references indexed in Scilit:
- Phosphonic Acid Monolayers for Binding of Bioactive Molecules to Titanium SurfacesLangmuir, 2006
- Multi-technique Comparison of Immobilized and Hybridized Oligonucleotide Surface Density on Commercial Amine-Reactive Microarray SlidesAnalytical Chemistry, 2006
- Evidence of Impurities in Thiolated Single-Stranded DNA Oligomers and Their Effect on DNA Self-Assembly on GoldLangmuir, 2005
- Interfacial Reactions in Confinement: Kinetics and Temperature Dependence of the Surface Hydrolysis of Polystyrene-block-poly(tert-butyl acrylate) Thin FilmsLangmuir, 2005
- Micro- and Nanofabrication of Robust Reactive Arrays Based on the Covalent Coupling of Dendrimers to Activated MonolayersLangmuir, 2004
- Characterization of Poly(l-lysine)-graft-Poly(ethylene glycol) Assembled Monolayers on Niobium Pentoxide Substrates Using Time-of-Flight Secondary Ion Mass Spectrometry and Multivariate AnalysisAnalytical Chemistry, 2004
- Interfacial Reactions in Confinement: Kinetics and Temperature Dependence of Reactions in Self-Assembled Monolayers Compared to Ultrathin Polymer FilmsLangmuir, 2003
- Reactivity in the Confinement of Self-Assembled Monolayers: Chain Length Effects on the Hydrolysis of N-Hydroxysuccinimide Ester Disulfides on GoldLangmuir, 2003
- High-Density, Covalent Attachment of DNA to Silicon Wafers for Analysis by MALDI-TOF Mass SpectrometryAnalytical Chemistry, 1997
- Contact-Angle Titrations of Mixed .omega.-Mercaptoalkanoic Acid/Alkanethiol Monolayers on Gold. Reactive vs Nonreactive Spreading, and Chain Length Effects on Surface pKa ValuesLangmuir, 1994