Fibrinolytic Activation During Long-term Support With the Heartmate II Left Ventricular Assist Device
- 1 January 2008
- journal article
- research article
- Published by Wolters Kluwer Health in Asaio Journal
- Vol. 54 (1) , 115-119
- https://doi.org/10.1097/mat.0b013e318161a987
Abstract
Human physiologic responses to pulsatile left ventricular assist devices (LVADs) are well understood; responses to the newer continuous flow pumps are not. Therefore, we evaluated the long-term effects of continuous flow LVAD support on fibrinolytic activation. Twelve recipients of an axial flow LVAD as destination therapy were assessed for fibrinolytic activation at 1, 3, 6, 9, and 12 months postimplantation. The fibrinolytic response and changes were assessed in terms of fibrinogen, D-dimer, plasma free hemoglobin, international normalized ratio (INR), and red blood cell (RBC) sedimentation rate. Bleeding and thromboembolic events were recorded. All fibrinolytic response parameters were elevated at baseline; mean RBC sedimentation rate was 51.8 mm/h, mean D-dimer was 3.95 nmol/L, and the mean fibrinogen was 356 mg/dl. The D-dimer and fibrinogen levels increased after LVAD implantation but returned to near-normal levels by 12 months. Red blood cell sedimentation rates increased indicating ongoing inflammation. Plasma free hemoglobin values decreased and remained low, an indicator of low shear rates and hemolysis. Three nonfatal bleeding events but no thromboembolic events were observed. Fibrinolytic responses initially increase after LVAD implantation but then gradually normalize.Keywords
This publication has 9 references indexed in Scilit:
- Platelet Activation Markers in Patients With Heart Assist DeviceArtificial Organs, 2005
- Direct thrombolytic therapy for intraventricular thrombosis in patients with the Jarvik 2000 left ventricular assist deviceThe Journal of Heart and Lung Transplantation, 2005
- Ventricular Assist Devices as a Bridge to Cardiac Transplantation: The Ottawa ExperienceArtificial Organs, 2004
- Worldwide Experience With the MicroMed DeBakey Ventricular Assist Device® as a Bridge to TransplantationCirculation, 2003
- Alterations in coagulation after implantation of a pulsatile Novacor LVAD and the axial flow micromed DeBakey LVADThe Annals of Thoracic Surgery, 2000
- Implantable LVAD insertion in patients with previous heart surgeryThe Journal of Heart and Lung Transplantation, 2000
- Evaluation of Regional Differences in Right Ventricular Systolic Function by Acoustic Quantification Echocardiography and Cine Magnetic Resonance ImagingCirculation, 1998
- Activation of coagulation and fibrinolytic pathways in patients with left ventricular assist devicesThe Journal of Thoracic and Cardiovascular Surgery, 1996
- Pathophysiologic Role of Contact Activation in Bleeding Followed by Thromboembolic Complications After Implantation of a Ventricular Assist DeviceAsaio Journal, 1995