Adaptive sensitivity encoding incorporating temporal filtering (TSENSE)†
Top Cited Papers
Open Access
- 16 April 2001
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 45 (5) , 846-852
- https://doi.org/10.1002/mrm.1113
Abstract
A number of different methods have been demonstrated which increase the speed of MR acquisition by decreasing the number of sequential phase encodes. The UNFOLD technique is based on time interleaving of k‐space lines in sequential images and exploits the property that the outer portion of the field‐of‐view is relatively static. The differences in spatial sensitivity of multiple receiver coils may be exploited using SENSE or SMASH techniques to eliminate the aliased component that results from undersampling k‐space. In this article, an adaptive method of sensitivity encoding is presented which incorporates both spatial and temporal filtering. Temporal filtering and spatial encoding may be combined by acquiring phase encodes in an interleaved manner. In this way the aliased components are alternating phase. The SENSE formulation is not altered by the phase of the alias artifact; however, for imperfect estimates of coil sensitivities the residual artifact will have alternating phase using this approach. This is the essence of combining temporal filtering (UNFOLD) with spatial sensitivity encoding (SENSE). Any residual artifact will be temporally frequency‐shifted to the band edge and thus may be further suppressed by temporal low‐pass filtering. By combining both temporal and spatial filtering a high degree of alias artifact rejection may be achieved with less stringent requirements on accuracy of coil sensitivity estimates and temporal low‐pass filter selectivity than would be required using each method individually. Experimental results that demonstrate the adaptive spatiotemporal filtering method (adaptive TSENSE) with acceleration factor R = 2, for real‐time nonbreath‐held cardiac MR imaging during exercise induced stress are presented. Magn Reson Med 45:846–852, 2001. Published 2001 Wiley‐Liss, Inc.Keywords
This publication has 7 references indexed in Scilit:
- Tailored SMASH image reconstructions for robust in vivo parallel MR imagingMagnetic Resonance in Medicine, 2000
- Cardiac real-time imaging using SENSEMagnetic Resonance in Medicine, 2000
- Unaliasing by Fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRIMagnetic Resonance in Medicine, 1999
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Segmentedk-space fast cardiac imaging using an echo-train readoutMagnetic Resonance in Medicine, 1999
- Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arraysMagnetic Resonance in Medicine, 1997
- Covariance matrix estimation errors and diagonal loading in adaptive arraysIEEE Transactions on Aerospace and Electronic Systems, 1988