Protease‐catalyzed incorporation of 18O into peptide fragments and its application for protein sequencing by electrospray and matrix‐assisted laser desorption/ionization mass spectrometry
- 1 January 1996
- journal article
- research article
- Published by Wiley in Electrophoresis
- Vol. 17 (5) , 945-953
- https://doi.org/10.1002/elps.1150170517
Abstract
Proteins were digested in normal and highly 18O-enriched water using proteases commonly employed for protein sequencing. The extent of 18O incorporation into the resulting peptide fragments was characterized by electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS). The endoproteinases trypsin, Lys-C and Glu-C incorporate two atoms of 18O, resulting in a mass shift of +4 D for the peptide fragments. This indicates that, following proteolytic cleavage, peptide products continue to interact with these proteases and undergo repeated binding/hydrolysis cycles, resulting in complete equilibration of both oxygens in the carboxy terminus of the fragments with oxygen from solvent water. In contrast, chymotrypsin and Asp-N incorporate only one atom of 18O, resulting in a mass shift of +2 D, indicating that after the cleavage step these proteases do not accept the peptides as substrates. In addition, it was found that the proteases trypsin, Glu-C, and Lys-C exhibit minor or nontypical sequence specificities, resulting in unexpected peptide fragments. These fragments incorporate only one 18O atom, indicating that they do not undergo further binding/hydrolysis cycles with the enzyme. Thus, it is possible to discriminate between enzyme-typical peptide fragments with mass shifts of +4 D and nontypical fragments with mass shifts of only +2 D. Based on these observations, protein digest strategies are described for the generation of 1:1 ion doublets spaced either by 2 or 4 D. In addition, the C-terminus of a protein can be identified by the absence of an ion doublet in the corresponding peptide fragment. In protein sequencing by mass spectrometry, digest protocols generating ion doublets provide the most clear-cut analytical results for the recognition of ion series in ESI-MS/MS and MALDI post-source decay (PSD) product ion specta. Only the mass spectrometric fragment ions of a C-terminal series show ion doublets spaced either by 2 or 4 D, whereas the fragment ions belonging to an N-terminal series remain unshifted. This assignment unequivocally reveals the direction of the identified sequence.Keywords
This publication has 12 references indexed in Scilit:
- Error-Tolerant Identification of Peptides in Sequence Databases by Peptide Sequence TagsAnalytical Chemistry, 1994
- Facile assignment of sequence ions of a peptide labelled with 18O at the carboxyl terminusRapid Communications in Mass Spectrometry, 1991
- [17] Preparation of labeled molecules by exchange with oxygen-18 waterPublished by Elsevier ,1990
- C-terminal peptide identification by fast atom bombardment mass spectrometryBiochemical Journal, 1988
- Preparation of oxygen-18-labeled lipoxygenase metabolites of arachidonic acidJournal of Mass Spectrometry, 1985
- Characterization of human interleukin 2 derived from Escherichia coliBiochemical Journal, 1985
- A new mass-spectrometric C-terminal sequencing technique finds a similarity between γ-interferon and α2-interferon and identifies a proteolytically clipped γ-interferon that retains full antiviral activityBiochemical Journal, 1983
- Amino acid sequence determination by g.l.c.-mass spectrometry of permethylated peptides. Optimization of the formation of chemical derivatives at the 2-10 nmol levelBiochemical Journal, 1983
- Preparation of stable isotope-incorporated peptide internal standards for field desorption mass spectrometry quantification of peptides in biologic tissueJournal of Mass Spectrometry, 1983
- Synthesis and back exchange of18O labeled amino acids for use as internal standards with mass spectrometryJournal of Mass Spectrometry, 1979