The x-ray emission analysis of noble-metal alloys was investigated critically to determine optimum conditions for accurate analysis. The analytical curves for the elements Cu, Pd, Pt, and Zn were found to be linear with a deviation of less than ±0.2%. However, a nonlinear relationship existed for gold and for silver. These discrepancies could not be eliminated by variation in sample preparation. An interelement effect due to x-ray absorption and enhancement was found and was corrected to an accuracy of 0.2% by means of a mathematical treatment suggested by Lucas-Tooth and Price. The analysis by x-ray emission can be accomplished in approximately one-tenth of the time necessary for conventional wet chemical methods.Keywords
This publication has 3 references indexed in Scilit:
- The theoretical derivation of fluorescent X-ray intensities from mixturesPublished by Elsevier ,2002
- X-Ray Spectrometric Analysis of Noble Metal Dental AlloysJournal of Research of the National Bureau of Standards Section A: Physics and Chemistry, 1964
- New procedure for the analysis of dental gold alloysJournal of Research of the National Bureau of Standards, 1938