Comparison of transaxial resolution in 180° and 360° SPECT with a rotating scintillation camera
- 1 April 1987
- journal article
- research article
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 13 (1) , 7-11
- https://doi.org/10.1007/bf00252638
Abstract
Using circular 180° and 360° SPECT acquisition modes the transaxial resolution of line sources in air and water were measured at different positions in the field of view. With the 180° acquisition mode, all line sources in air located off the axis of camera rotation (AoR) showed an oval distortion. This distortion was systematically related to the starting point of the rotating detector. On axis line sources in air were undistorted, regardless of the 180° acquisition starting angle. The 360° acquisition images of the line sources in air showed a similar effect but in a very mild form. In water, transaxial reconstructions of line sources (off axis) showed an enhancement of the oval distortion for both the 180° and 360° acquisitions. Computer simulations of the line source measurements were performed and correlated well with the experimental data. The line source results are explainable by the inherent depth dependent response of the scintillation camera. In clinical SPECT studies, distortions of this nature will be most appreciable with 180° imaging of small organs that are located off the AoR.This publication has 19 references indexed in Scilit:
- The measurement of resolution in single photon emission computerised tomographyPhysics in Medicine & Biology, 1984
- 180 degrees compared with 360 degrees sampling in SPECT.1982
- LESION DETECTION WITH SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY (SPECT) COMPARED WITH CONVENTIONAL IMAGING1982
- COMPARISON OF 180-DEGREES AND 360-DEGREES DATA-COLLECTION IN TL-201 IMAGING USING SINGLE-PHOTON EMISSION COMPUTERIZED-TOMOGRAPHY (SPECT) - CONCISE COMMUNICATION1982
- COMPARATIVE-STUDY OF THALLIUM EMISSION MYOCARDIAL TOMOGRAPHY WITH 180-DEGREES AND 360-DEGREES DATA-COLLECTION1982
- Multiple Photon Coincidence TomographySeminars in Nuclear Medicine, 1980
- Physical attributes of single-photon tomography.1980
- Radionuclide axial tomography by half back-projectionPhysics in Medicine & Biology, 1978
- Emission Computer Assisted Tomography with Single-Photon and Positron Annihilation Photon EmittersJournal of Computer Assisted Tomography, 1977
- Three-dimensional Reconstruction from Radiographs and Electron Micrographs: Application of Convolutions instead of Fourier TransformsProceedings of the National Academy of Sciences, 1971