Thermal Boundary Resistance between Solids and Helium below 1°K

Abstract
Results are reported from measurements of the thermal boundary resistance between liquid He3 and copper or epoxy resin, and between solid He3 or liquid He4 and copper. Measurements were made in the range 0.05 to 0.9°K and at pressures up to 395 psi. No quantitative agreement has been found with theory. Above 0.11°K, the thermal boundary resistance of liquid He3 and liquid He4 both have a temperature dependence stronger than T3. Below 0.11°K the thermal boundary resistance of He3 varies as T3 over the full pressure range in the liquid. In the case of He4 at low pressure, however, the stronger temperature dependence continues to the lowest temperature measured (0.075°K). It is not clear whether the qualitative difference in the behavior of liquid He3 and liquid He4 is associated with zero sound in liquid He3.

This publication has 17 references indexed in Scilit: