Abstract
Adiabatic fast passage (AFP) is used in noninvasive quantitative perfusion experiments to invert (or label) arterial spins. Continuous arterial spin labeling (CASL) experiments conducted in vivo often assume the inversion efficiency based on the labeling field and steady flow conditions, without direct verification. In practice, the labeling field used in CASL is often amplitude‐ and duty cycle‐limited due to hardware or specific absorption rate constraints. In this study, the effects of the labeling field amplitude and duty cycle, and flow dynamics on the inversion efficiency of AFP were examined under steady flow conditions in a saline flow phantom. The experimental results were in general agreement with models based on Zhernovoi's theory except at high labeling field amplitudes, when the spin inversion times are at least half of the duration of the labeling pulse. The nonlinear relation observed between the inversion efficiency and the labeling duty cycle implies that the practice of linear derating the inversion efficiency with the labeling duty cycle may be prone to significant error. A secondary finding was that the T1 of the flowing fluid could be calculated based on the flow dynamics after varying the flow rate. Magn Reson Med 47:709–719, 2002.Keywords
This publication has 25 references indexed in Scilit:
- Perfusion quantitation in transplanted rat kidney by MRI with arterial spin labelingKidney International, 1998
- Correction for vascular artifacts in cerebral blood flow values measured by using arterial spin tagging techniquesMagnetic Resonance in Medicine, 1997
- Perfusion imaging of the human brain at 1.5 T using a single‐shot EPI spin tagging approachMagnetic Resonance in Medicine, 1996
- Quantification of relative cerebral blood flow change by flow‐sensitive alternating inversion recovery (FAIR) technique: Application to functional mappingMagnetic Resonance in Medicine, 1995
- Pulsatile Velocity Measurements in a Model of the Human Abdominal Aorta Under Resting ConditionsJournal of Biomechanical Engineering, 1994
- Pulsatile Velocity Measurements in a Model of the Human Abdominal Aorta Under Simulated Exercise and Postprandial ConditionsJournal of Biomechanical Engineering, 1994
- Continuous inversion angiographyMagnetic Resonance in Medicine, 1993
- Measurement of rat brain perfusion by NMR using spin labeling of arterial water: In vivo determination of the degree of spin labelingMagnetic Resonance in Medicine, 1993
- Magnetic relaxation in blood and blood clotsMagnetic Resonance in Medicine, 1990
- Projection angiograms of blood labeled by adiabatic fast passageMagnetic Resonance in Medicine, 1986