Some factors affecting bubble formation with catheter-mediated defibrillator pulses.
- 1 March 1986
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 73 (3) , 525-538
- https://doi.org/10.1161/01.cir.73.3.525
Abstract
Factors affecting bubble formation during delivery of defibrillator pulses to arrhythmogenic cardiac tissue via a catheter are unknown. We investigated the role of energy, electrode surface area, interelectrode distance, and electrode polarity on bubble formation and on current and voltage waveforms during delivery of damped sinusoidal discharges from a standard defibrillator to anticoagulated bovine blood. Gas composition was studied with mass spectrometry. Defibrillator energy settings were varied between 5 and 360 J. The principal catheter used for study was a Medtronic 6992A lead. Additional electrodes tested included 2, 5, and 10 mm long No. 6F, 7F, and 8F copper electrodes. Interelectrode distances used to assess the effect of anode-cathode spacing were 1, 5, 10, and 20 cm. Bubble volume increased linearly from 0.043 to 0.134 ml per cathodal pulse and from 0.030 to 3.50 ml per anodal pulse as energy settings were increased from 5 to 360 J (r = .99). Typical smooth waveforms for both current and volt...This publication has 14 references indexed in Scilit:
- Effect of damped sine-wave shocks on catheter dielectric strengthThe American Journal of Cardiology, 1985
- The daytime breath hydrogen profile: technical aspects and normal patternClinica Chimica Acta; International Journal of Clinical Chemistry, 1985
- Intracardiac contrast echoes during transvenous His bundle ablation.Heart, 1985
- Treatment of tachycardias associated with the Wolff-Parkinson-White syndrome by transvenous electrical ablation of accessory pathways.Heart, 1985
- Attempted nonsurgical electrical ablation of accessory pathways via the coronary sinus in the Wolff-Parkinson-White syndromeJournal of the American College of Cardiology, 1984
- Effects of energy delivery via a His bundle catheter during closed chest ablation of the atrioventricular conduction system.Journal of Clinical Investigation, 1983
- Junctional automatic ectopic tachycardia: New proposed treatment by transcatheter His bundle ablationAmerican Heart Journal, 1983
- Closed chest modification of atrioventricular conduction system in man for treatment of refractory supraventricular tachycardia.Heart, 1983
- Catheter Technique for Closed-Chest Ablation of the Atrioventricular Conduction SystemNew England Journal of Medicine, 1982