Real-time 3D motion tracking for small animal brain PET
- 29 April 2008
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 53 (10) , 2651-2666
- https://doi.org/10.1088/0031-9155/53/10/014
Abstract
High-resolution positron emission tomography (PET) imaging of conscious, unrestrained laboratory animals presents many challenges. Some form of motion correction will normally be necessary to avoid motion artefacts in the reconstruction. The aim of the current work was to develop and evaluate a motion tracking system potentially suitable for use in small animal PET. This system is based on the commercially available stereo-optical MicronTracker S60 which we have integrated with a Siemens Focus-220 microPET scanner. We present measured performance limits of the tracker and the technical details of our implementation, including calibration and synchronization of the system. A phantom study demonstrating motion tracking and correction was also performed. The system can be calibrated with sub-millimetre accuracy, and small lightweight markers can be constructed to provide accurate 3D motion data. A marked reduction in motion artefacts was demonstrated in the phantom study. The techniques and results described here represent a step towards a practical method for rigid-body motion correction in small animal PET. There is scope to achieve further improvements in the accuracy of synchronization and pose measurements in future work.Keywords
This publication has 22 references indexed in Scilit:
- Laboratory environments and rodents' behavioural needs: a reviewLaboratory Animals, 2006
- Real-time, high-accuracy 3D tracking of small animals for motion-corrected SPECT imagingPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2005
- The use of molecular sieves to produce point sources of radioactivityPhysics in Medicine & Biology, 2004
- The design and implementation of a motion correction scheme for neurological PETPhysics in Medicine & Biology, 2003
- Correction for head movements in positron emission tomography using an optical motion-tracking systemIEEE Transactions on Nuclear Science, 2002
- Cerebral perfusion during anesthesia with fentanyl, isoflurane, or pentobarbital in normal rats studied by arterial spin‐labeled MRIMagnetic Resonance in Medicine, 2001
- Stress impairs prefrontal cortical function in rats and monkeys: role of dopamine D1 and norepinephrine α-1 receptor mechanismsPublished by Elsevier ,2000
- Estimation of Latency Changes and Relative Amplitudes in Somatosensory Evoked Potentials Using Wavelets and RegressionComputers and Biomedical Research, 1999
- A practical 3D tomographic method for correcting patient head motion in clinical SPECTIEEE Transactions on Nuclear Science, 1999
- Predicting error in rigid-body point-based registrationIEEE Transactions on Medical Imaging, 1998