The Suppression of Destructive Sparks in Parallel Plate Proportional Counters
- 1 January 1984
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 31 (1) , 107-110
- https://doi.org/10.1109/tns.1984.4333220
Abstract
We find that high energy background events produce localised sparks in parallel plate counters when operated in the proportional mode. These sparks increase dead-time and lead to degradation ranging from electrode damage to spurious pulsing and continuous breakdown. The problem is particularly serious in low energy photon detectors for X-ray astronomy which are required to have lifetimes of several years in the high radiation environment of space. For the parallel plate imaging detector developed for the European X-ray Observatory Satellite (EXOSAT) we investigate quantitatively the spark thresholds, spark rates and degradation processes. We discuss the spark mechanism, pointing out differences from the situation in spark chambers and counters. We show that the time profile of the sparks allows us to devise a spark suppression system which reduces the degradation rate by a factor of ~200.Keywords
This publication has 12 references indexed in Scilit:
- Improved Energy Resolution Capability of an Imaging Proportional Counter Using Electron Counting TechniquesIEEE Transactions on Nuclear Science, 1983
- Application of the Wedge and Strip Anode to Position Sensing with Microchannel Plates and Proportional CountersIEEE Transactions on Nuclear Science, 1983
- Lifetime of proportional counters filled with xenon-methane and argon-methaneNuclear Instruments and Methods in Physics Research, 1982
- A Parallel Grid Imaging Proportional Counter Optimized for Detection of Low Brightness Stellar XUV-SourcesIEEE Transactions on Nuclear Science, 1980
- The multistep avalanche chamber: A new family of fast, high-rate particle detectorsNuclear Instruments and Methods, 1979
- The Parallel Plate Imaging Proporticnal Counter and Its Performance with Different Gas MixturesIEEE Transactions on Nuclear Science, 1979
- The hybrid chamber: A proportional chamber with gated spark readoutNuclear Instruments and Methods, 1972
- Comments on the ageing effect of gas-filled proportional countersJournal of Physics E: Scientific Instruments, 1969
- Parallel-Plate CountersReview of Scientific Instruments, 1949
- ber die als Nachwirkung von Gasentladungen an den Elektroden auftretende spontane Elektronenemission und die Feldelektronenemission an d nnen IsolatorschichtenThe European Physical Journal A, 1939