Methods for transferring patient and plan data between radiotherapy treatment planning systems.
- 1 July 1997
- journal article
- Published by Oxford University Press (OUP) in The British Journal of Radiology
- Vol. 70 (835) , 740-749
- https://doi.org/10.1259/bjr.70.835.9245886
Abstract
The effectiveness of conformal radiotherapy can ultimately only be assessed by the use of clinical trials. As large multicentre clinical trials become more widespread, methods of transferring patient and plan data between radiotherapy treatment planning systems become increasingly important. In this paper, the general strategy for the transfer of data is discussed, and also illustrated with reference to two specific systems: TARGET 2 (GE Medical Systems) and VOXELPLAN (DKFZ-Heidelberg). The transfer method involves using a computer program to translate the data formats used by each of the two systems for CT scans, patient outlines, plan information and block descriptions. This paper does not address the question of transferring beam data between systems: beam data must first be entered separately into both machines. The physical concepts encountered when transferring plans are described, with specific reference to the two planning systems used. Differences in the strategies used by the two planning systems for definition of irregular field shapes are compared. The dose calculations used by the two systems are also briefly evaluated. Isodoses produced by VOXELPLAN around a circular target volume are found to be up to 3 mm different in location to those produced by TARGET 2, owing to the use of a smooth field shape contour as opposed to a stepped field shape which closely models the leaves of a multileaf collimator. In general, dose distributions generated by both systems are comparable, but some differences are found in the presence of large tissue inhomogeneities. It is concluded that the transfer of patient and plan data between two different treatment planning systems is feasible, provided that any differences in field shape definition methods or dose calculation methods between the two systems are understood.Keywords
This publication has 7 references indexed in Scilit:
- The optimisation of wedge filters in radiotherapy of the prostateRadiotherapy and Oncology, 1995
- The choice of technique for MLC conformal therapy of the prostateRadiotherapy and Oncology, 1995
- The acceptability of a multileaf collimator as a replacement for conventional blocksRadiotherapy and Oncology, 1995
- A comparison of conventional ‘forward planning’ with inverse planning for 3D conformal radiotherapy of the prostateRadiotherapy and Oncology, 1995
- The design and performance characteristics of a multileaf collimatorPhysics in Medicine & Biology, 1994
- Commissioning and quality assurance of treatment planning computersPublished by Elsevier ,1993
- The storage and manipulation of radiation dose data in a small digital computerThe British Journal of Radiology, 1974