Interobserver and Intraobserver Reliability of Venous Transcranial Color‐Coded Flow Velocity Measurements
- 1 October 2001
- journal article
- Published by Wiley in Journal of Neuroimaging
- Vol. 11 (4) , 385-392
- https://doi.org/10.1111/j.1552-6569.2001.tb00067.x
Abstract
Background and Purpose. Venous transcranial color‐coded duplex sonography is a new technique for noninvasive evaluation of the intracranial venous system. However, the interobserver and intraobserver reliability of this method is unclear. Methods. In 23 healthy volunteers (30 ± 7.3 years of age), the deep middle cerebral vein (dMCV), basal vein (BV), vein of Galen (VG), and straight (SRS), transverse (TS), and superior sagittal (SSS) sinuses in addition to the arterial segments of the circle of Willis were insonated through the temporal bone window on 2 consecutive days by 2 experienced examiners. The examiners were blinded to each other's results. The interobserver and intraobserver reliability was calculated using a method described by Bland and Altman, resulting in 2‐SD confidence intervals. Results. Non‐angle‐corrected and angle‐corrected systolic and end diastolic venous flow velocities (FV) were in good accordance with published normal values, ranging between 8.6 and 19.2 cm/s. The interobserver reliabilities for non‐angle‐corrected systolic FVs in the dMCV, BV, VG, SRS, and TS were ±1.8, 2.4, 2.6, 3.3, and 4.6 cm/s; for angle‐corrected systolic FVs, the interobserver reliabilities were ±2.5, 3.1, 13.9, 11.6, and 7.7 cm/s. The intraobserver reliabilities for non‐angle‐corrected systolic FVs in the dMCV, BV, VG, SRS, and TS were ±2.9, 3.2, 2.6, 3.2, and 6.1 cm/s; for angle‐corrected systolic FVs, the intraobserver reliabilities were 3.2, 3.7, 13.9, 11.6, and 7.5 cm/s. Angle correction was not attempted for the SSS. The interobserver and intraobserver reliabilities for systolic FVs in the SSS were ±3.3 and ±3.3 cm/s, respectively. Conclusions. Intracranial venous FV can be measured with a high interobserver and intraobserver reliability in healthy human subjects. Intraobserver reliability was higher for cerebral veins than for dural sinuses, predisposing them for follow‐up examinations; however, angle correction for venous FV in the VG and the SRS is not advisable.Keywords
This publication has 11 references indexed in Scilit:
- Assessment of Intracranial Venous Hemodynamics in Normal Individuals and Patients With Cerebral Venous ThrombosisStroke, 1999
- Echocontrast-enhanced transcranial color-coded sonography for the diagnosis of transverse sinus venous thrombosis.Stroke, 1997
- Transcranial Color‐Coded Real‐Time Sonography of Intracranial VeinsJournal of Neuroimaging, 1995
- Quantitative Measurements of Blood Flow Velocity in Basal Cerebral Arteries with Transcranial Duplex Color-Flow Imaging: A Comparative Study with Conventional Transcranial Doppler SonographyJournal of Neuroimaging, 1994
- Transcranial color-coded sonography of the basal cerebral circulation. Reference data from 115 volunteers.Stroke, 1994
- A validation study on the intraobserver reproducibility of transcranial color-coded duplex sonography velocity measurementsUltrasound in Medicine & Biology, 1994
- Comparative study of transcranial color duplex sonography and transcranial Doppler sonography in adultsJournal of Neurosurgery, 1993
- Evaluation of the vertebrobasilar-posterior system by transcranial color duplex sonography in adults.Stroke, 1992
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986