Removal of viscoelastic materials after experimental cataract surgery in vitro
- 1 January 1992
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 18 (1) , 3-6
- https://doi.org/10.1016/s0886-3350(13)80376-8
Abstract
The one significant complication of viscoelastic materials is that they may cause postoperative intraocular pressure rise. We investigated the rate and ease of removal of various viscoelastics using the Miyake video technique. Five viscoelastics were investigated: sodium hyaluronate (Healon), Healon GV, chondroitin sulfatesodium hyaluronate (Viscoat), hydroxypropylmethylcellulose (Occucoat), and polyacrylamide (Orcolon). The viscoelastics were dyed with fluorescein and, after filling the capsular bag with a viscoelastic material, a posterior chamber intraocular lens (IOL) was implanted. The viscoelastic was then aspirated using an automated irrigation/aspiration device. Healon and Healon GV were completely removed within 20 to 25 seconds. Viscoat adhered to the lens capsule and to the posterior surface of the IOL and cooplete removal required approximately 3.5 minutes. Most Occucoat and Orcolon was aspirated within one minute; however, removal was completed only after three minutes. Removal of Healon and Healon GV was faster and more complete than removal of the other viscoelastics. Whether a small amount of viscoelastic left in the eye or trapped behind the IOL optic has any clinical significance has to be studied.Keywords
This publication has 7 references indexed in Scilit:
- Viscoelastic substances in ophthalmologySurvey of Ophthalmology, 1990
- Postoperative intraocular pressure rises: A comparison of Healon, Amvisc, and ViscoatJournal of Cataract & Refractive Surgery, 1989
- Experimental evaluation of a synthetic viscoelastic material on intraocular pressure and corneal endotheliumJournal of Cataract & Refractive Surgery, 1989
- A Comparison of the Efficacy and Toxicity of and Intraocular Pressure Response to Viscous Solutions in the Anterior ChamberArchives of Ophthalmology (1950), 1986
- Intraocular pressure in the first days after implantation of posterior chamber lenses with the use of sodium hyaluronate (Healon®)Acta Ophthalmologica, 1986
- Comparison of the Effects of Viscoat and Healon on Postoperative Intraocular PressureAmerican Journal of Ophthalmology, 1985
- Intraocular pressure after cataract surgery with Healon®American Intra-Ocular Implant Society Journal, 1985