Validation of the ‘internal reference technique’ for calibrating microdialysis catheters in situ
- 1 April 1995
- journal article
- clinical trial
- Published by Wiley in Acta Physiologica Scandinavica
- Vol. 153 (4) , 375-380
- https://doi.org/10.1111/j.1748-1716.1995.tb09875.x
Abstract
In vivo calibration of microdialysis catheters with [3H]glucose as internal reference was done in rat (n= 17) and human (n= 12) subcutaneous tissue. The estimated interstititial glucose level was compared owth the glucose concentration in venous plasma which, in turn, has been shown to be identical to the interstitial glucose concentration. In subcutaneous tissue of anaesthetized male Sprageue‐Dawley rats, interstitial glucose was significantly overestimated (43%, P < 0.005, n= 8, and 19%, P < 0.005, n=9, in nornoglycaemic and hyperglycaemic animals, respectively). Furthermore, fractional outflux of [3H]glucose decreased continuously during prolonged perfusion of the microdialysis catheter. Incontrast, in human subcutaneous tissue microdialysed with two catheters, correct measurements of interstitial glucose could be achieved and the precision was comparableto that obtained with equilibration calibraton in vivo. The average relative error of the mean result of two catheters was 8.9% at a perfusate flow rate of 1 μL min‐1.It may be suggested that calibration in in vivo of microdialysis catheters with internal references may be used in human subcutaneous tissue. However, it is necessary to validate the calibration technique in each different tissue under reproducible experimental conditions since accumulation of the reference substance in the tissue may create artefactual results.Keywords
This publication has 11 references indexed in Scilit:
- Glycerol production in subcutaneous adipose tissue in lean and obese humans.Journal of Clinical Investigation, 1992
- Microdialysis—a new and promising method in clinical medicineJournal of Internal Medicine, 1991
- Microdialysis—principles and applications for studies in animals and manJournal of Internal Medicine, 1991
- Microdialysis of adipose tissueJournal of Internal Medicine, 1991
- Microdialysis sampling of the neuronal environment in basic and clinical researchJournal of Internal Medicine, 1991
- Changes in cerebral blood flow do not directly affect in vivo recovery of extracellular lactate through microdialysis probeNeuroscience Letters, 1991
- Determination of Brain Interstitial Concentrations by MicrodialysisJournal of Neurochemistry, 1989
- Cellular reactions to implantation of a microdialysis tube in the rat hippocampusActa Neuropathologica, 1987
- Mass transfer in brain dialysis devices—a new method for the estimation of extracellular amino acids concentrationJournal of Neuroscience Methods, 1985