Effect of tissue heterogeneity on quantification in positron emission tomography
- 1 July 1995
- journal article
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 22 (7) , 652-663
- https://doi.org/10.1007/bf01254567
Abstract
As a result of the limited spatial resolution of positron emission tomographic scanners, the measurements of physiological parameters are compromised by tissue heterogeneity. The effect of tissue heterogeneity on a number of parameters was studied by simulation and an analytical method. Five common tracer models were assessed. The input and tissue response functions were assumed to be free from noise and systematic errors. The kinetic model was assumed to be perfect. Two components with different kinetics were mixed in different proportions and contrast with respect to the model parameters. Different experimental protocols were investigated. Of three methods investigated for the measurement of cerebral blood flow (CBF) (steady state, dynamic, integral), the second one was least sensitive to errors caused by tissue heterogeneity and the main effect was an underestimation of the distribution volume. With the steady state method, errors in oxygen extraction fraction caused by tissue heterogeneity were always found to be less than the corresponding errors in CBF. For myocardial blood flow the steady state method was found to perform better than the bolus method. The net accumulation of substrate (i.e. rCMRgjc in the case of glucose analogs) was found to be comparatively insensitive to tissue heterogeneity. Individual rate constants such ask 2 andk 3 for efflux and metabolism of the substrate in the pool of unmetabolized substrate in the tissue, respectively, were found to be more sensitive. In studies of radioligand binding, using only tracer doses, the effect of tissue heterogeneity on the parameterk on ·B max could be considerable. In studies of radioligand binding using a protocol with two experiments, one with high and one with low specific activity,B max was found to be insensitive whileK d was very sensitive to tissue heterogeneity.Keywords
This publication has 38 references indexed in Scilit:
- Measurement of regional myocardial blood flow using C 15 O 2 and positron emission tomography: comparison of tracer modelsClinical Physics and Physiological Measurement, 1992
- Measurement of Cerebral Monoamine Oxidase B Activity Using L-[11C]Deprenyl and Dynamic Positron Emission TomographyJournal of Cerebral Blood Flow & Metabolism, 1991
- Model of Kinetic Behavior of Deoxyglucose in Heterogeneous Tissues in Brain: A Reinterpretation of the Significance of Parameters Fitted to Homogeneous Tissue ModelsJournal of Cerebral Blood Flow & Metabolism, 1991
- PET studies of dopamine receptor distribution using [18F]fluoroethylspiperone: findings in disorders related to the dopaminergic systemJournal Of Neural Transmission-Parkinsons Disease and Dementia Section, 1990
- Physical characteristics of TTV03, a new high spatial resolution time-of-flight positron tomographIEEE Transactions on Nuclear Science, 1990
- Models for in vivo Kinetic Interactions of Dopamine D2-Neuroreceptors and 3-(2'-[18F]Fluoroethyl)Spiperone Examined with Positron Emission TomographyJournal of Cerebral Blood Flow & Metabolism, 1989
- Noninvasive quantitation of myocardial blood flow in human subjects with oxygen-15-labeled water and positron emission tomographyJournal of the American College of Cardiology, 1989
- Quantification of Neuroreceptors in the Living Human Brain. I. Irreversible Binding of LigandsJournal of Cerebral Blood Flow & Metabolism, 1986
- A Simplified in vivo Autoradiographic Strategy for the Determination of Regional Cerebral Blood Flow by Positron Emission Tomography: Theoretical Considerations and Validation Studies in the RatJournal of Cerebral Blood Flow & Metabolism, 1982
- Minuit - a system for function minimization and analysis of the parameter errors and correlationsComputer Physics Communications, 1975