Interatrial septum pacing: A new approach to prevent recurrent atrial fibrillation.
- 1 January 1999
- journal article
- research article
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 3 (1) , 35-43
- https://doi.org/10.1023/a:1009867305678
Abstract
Background. There are a variety of approaches to the prevention of atrial fibrillation (AF) with pacing. Aim of this study was to test the safety and feasibility of interatrial septum pacing at the posterior triangle of Koch for AF prevention and to exclude potential arrhythmic effects. Matherial and Methods.Interatrial septum pacing was performed in 34 patients (21 males, 13 females, mean age 69±12 years): 9 without a history and clinical evidence of atrial fibrillation (AF) (6 with sinus bradycardia, 2 with second-degree AV block, and 1 with carotid sinus hypersensitivity) and 25 with sinus bradycardia and paroxysmal atrial fibrillation (PAF) (mean symptomatic episodes/month 6.2±10). In all patients a screw-in bipolar lead was positioned in the interatrial septum superiorly to the coronary sinus. Results.At implant the mean P wave amplitude was 2.5±1.5 mV, the pacing threshold was 1±0.6 V and the impedance was 907±477 Ohm. Mean P wave duration was 118±17 ms in sinus rhythm and 82±15 during interatrial septum pacing (p < 0.001). During a mean follow-up period of 10±7 months, no patients without atrial tachyarrhythmias before implantation experienced AF. During a 9±6 months follow-up we observed only 2 symptomatic arrhythmia recurrences between AF patients (mean symptomatic episodes/month 0.006±0.0022) (p < 0.01 vs before implant period). Conclusions. Our data indicate that interatrial septal pacing is safe and feasible. A significant less incidence of arrhythmic episodes has been observed during follow-up. Further controlled randomized prospective studies are necessary to establish the exact role of this technique respect to conventional or multisite stimulation when patients with paroxysmal AF need to be permanently paced.Keywords
This publication has 23 references indexed in Scilit:
- Successful Catheter Ablation of Atrial FibrillationJournal of Cardiovascular Electrophysiology, 1994
- A New Pacing Algorithm for Overdrive Suppression of Atrial FibrillationPacing and Clinical Electrophysiology, 1994
- Radiofrequency Catheter Ablation in Unusual Mechanisms of Atrial Fibrillation:Journal of Cardiovascular Electrophysiology, 1994
- Symptoms, Cardiovascular Risk Profile and Spontaneous ECG in Paced Patients: A Five‐Year Follow‐Up StudyPacing and Clinical Electrophysiology, 1990
- Morbidity and Mortality of Patients with Sinus Node Disease: Comparative Effects of Atrial and Ventricular PacingPacing and Clinical Electrophysiology, 1990
- Influence of cardiac pacing mode on the long-term development of atrial fibrillationThe American Journal of Cardiology, 1989
- DDD Pacing: An Effective Treatment Modality for Recurrent Atrial ArrhythmiasPacing and Clinical Electrophysiology, 1988
- Long-term pacing in sinus node disease: Effects of stimulation mode on cardiovascular morbidity and mortalityAmerican Heart Journal, 1988
- The Natural History of Lone Atrial FibrillationNew England Journal of Medicine, 1987
- Long-term Prevention of Vagal Atrial Arrhythmias by Atrial Pacing at 90/Minute: Experience with 6 CasesPacing and Clinical Electrophysiology, 1983