Cost Identification of Abdominal Aortic Aneurysm Imaging by Using Time and Motion Analyses
- 1 April 2000
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 215 (1) , 63-70
- https://doi.org/10.1148/radiology.215.1.r00ap4863
Abstract
To compare the costs of performing helical computed tomographic (CT) angiography with three-dimensional rendering versus intraarterial digital subtraction angiography (DSA) for preoperative imaging of abdominal aortic aneurysms (AAAs). A single observer determined the variable direct costs of performing nine intraarterial DSA and 10 CT angiographic examinations in age- and general health-matched patients with AAA by using time and motion analyses. All personnel directly involved in the cases were tracked, and the involvement times were recorded to the nearest minute. All material items used during the procedures were recorded. The cost of labor was determined from personnel reimbursement data, and the cost of materials, from vendor pricing. The variable direct costs of laboratory tests and using the ambulatory treatment unit for postprocedural monitoring, as well as all fixed direct costs, were assessed from hospital accounting records. The total costs were determined for each procedure and compared by using the Student t test and calculating the CIs. The mean total direct cost of intraarterial DSA (+/- SD) was $1,052 +/- 71, and that of CT angiography was $300 +/- 30, which are significantly different (P < 4.1 x 10(-11)). With 95% confidence, intraarterial DSA cost 3.2-3.7 times more than CT angiography for the assessment of AAA. Assuming equal diagnostic utility and procedure-related morbidity, institutions may have substantial cost savings whenever CT angiography can replace intraarterial DSA for imaging AAAs.Keywords
This publication has 28 references indexed in Scilit:
- CT angiography of potential renal transplant donors.RadioGraphics, 1998
- Renal artery stenosis: detection and quantification with spiral CT angiography versus optimized digital subtraction angiography.Radiology, 1997
- Evaluation of thoracic aortic disease with the use of helical CT and multiplanar reconstructions: comparison with surgical findings.Radiology, 1996
- Supra- and juxtarenal aneurysms of the abdominal aorta: preoperative assessment with thin-section spiral CT.Radiology, 1996
- Comparison of the Utility of CT Scans and Intravascular Ultrasound in Endovascular Aortic GraftingAnnals of Vascular Surgery, 1995
- Detection of circle of Willis aneurysms in patients with acute subarachnoid hemorrhage: a comparison of CT angiography and digital subtraction angiography.American Journal of Roentgenology, 1995
- Delayed rupture of aortic aneurysms following endovascular stent graftingThe American Journal of Surgery, 1995
- Assessment of living renal donors with spiral CT.Radiology, 1995
- Treatment of complex abdominal aortic aneurysms by a combination of endoluminal and extraluminal aortofemoral graftsJournal of Vascular Surgery, 1994
- CT angiography: application to the evaluation of carotid artery stenosis.Radiology, 1993