High-resolution solid modeling of biological samples imaged with 3D fluorescence microscopy
- 6 June 2006
- journal article
- research article
- Published by Wiley in Microscopy Research and Technique
- Vol. 69 (8) , 648-655
- https://doi.org/10.1002/jemt.20332
Abstract
Optical‐sectioning, digital fluorescence microscopy provides images representing temporally‐ and spatially‐resolved molecular‐scale details of the substructures of living cells. To render such images into solid models for further computational analyses, we have developed an integrated system of image acquisition, processing, and rendering, which includes a new empirical technique to correct for axial distortions inherent in fluorescence microscopy due to refractive index mismatches between microscope objective immersion medium, coverslip glass, and water. This system takes advantage of the capabilities of ultra‐high numerical aperture objectives (e.g. total internal reflection fluorescence microscopy) and enables faithful three‐dimensional rendering of living cells into solid models amenable to further computational analysis. An example of solid modeling of bovine aortic endothelial cells and their nuclei is presented. Since many cellular level events are temporally and spatially confined, such integrated image acquisition, processing, rendering, and computational analysis, will enable, in silico, the generation of new computational models for cell mechanics and signaling. Microsc. Res. Tech., 2006.Keywords
This publication has 28 references indexed in Scilit:
- Evidence for Ectopic Neurotransmission at a Neuronal SynapseScience, 2005
- Visualizing the mechanical activation of SrcNature, 2005
- A procedure to determine the correct thickness of an object with confocal microscopy in case of refractive index mismatchJournal of Microscopy, 2005
- Force-induced focal adhesion translocation: effects of force amplitude and frequencyAmerican Journal of Physiology-Cell Physiology, 2004
- Dynamics of the mammalian nucleus: can microscopic movements help us to understand our genes?Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences, 2004
- Real-time visualization of the cytoskeleton and effector functions in T cellsCurrent Opinion in Immunology, 2004
- Cell mechanics and mechanotransduction: pathways, probes, and physiologyAmerican Journal of Physiology-Cell Physiology, 2004
- Improvement in volume estimation from confocal sections after image deconvolutionMicroscopy Research and Technique, 2004
- Refractive-index-mismatch induced aberrations in single-photon and two-photon microscopy and the use of aberration correctionJournal of Biomedical Optics, 2001
- Artifacts in computational optical-sectioning microscopyJournal of the Optical Society of America A, 1994