Atmospheric Pressure MALDI with Pulsed Dynamic Focusing for High-Efficiency Transmission of Ions into a Mass Spectrometer
- 25 March 2004
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 76 (9) , 2462-2469
- https://doi.org/10.1021/ac0353177
Abstract
The atmospheric pressure (AP) matrix-assisted laser desorption/ionization (MALDI) technique described to date has proven to be a convenient and rapid method for soft ionization of biomolecules. However, this technique, like other AP ionization methods, has so far suffered from a low efficiency in transmitting ions from atmospheric pressure into the vacuum of the mass spectrometer (MS). In this work, a novel technique we termed pulsed dynamic focusing, or PDF, which improves the ion transmission efficiency and sensitivity of AP-MALDI by over an order of magnitude, is described. Pulsed dynamic focusing operates on the basis of pulsing a high-voltage extraction field to zero, when ions are just outside of the MS entrance, to allow the intake gas flow of the MS to effectively entrain the ions into the MS. Results from application of the PDF technique to an AP-MALDI ion trap MS demonstrated that in comparison to static AP-MALDI operation (1) up to 2.1 times more ions from a given laser shot could be transferred into the MS, (2) applying higher voltages in combination with the switching scheme yielded up to 1.6-times-higher ion intensities, and (3) a 3-times-larger laser spot area could be utilized. The combination of these factors produced an enhancement in throughput and sensitivity, as measured by the ions detected per unit time, of over 12 times for a digest sample of bovine serum albumin. In addition, the PDF technique proved to make AP-MALDI less sensitive to laser positioning, creating a more robust ion source in comparison to static AP-MALDI.Keywords
This publication has 7 references indexed in Scilit:
- Fragmentation of cationized phosphotyrosine containing peptides by atmospheric pressure MALDI/Ion trap mass spectrometryJournal of the American Society for Mass Spectrometry, 2003
- An atmospheric pressure matrix‐assisted laser desorption/ionization ion trap with enhanced sensitivityRapid Communications in Mass Spectrometry, 2003
- A High Repetition Rate (1 kHz) Microcrystal Laser for High Throughput Atmospheric Pressure MALDI-Quadrupole-Time-of-Flight Mass SpectrometryAnalytical Chemistry, 2002
- Recent developments in atmospheric pressure MALDI mass spectrometryInternational Journal of Mass Spectrometry, 2002
- Fragmentation of phosphopeptides by atmospheric pressure MALDI and ESI/ion trap mass spectrometryJournal of the American Society for Mass Spectrometry, 2002
- Structural analysis of oligosaccharides by atmospheric pressure matrix‐assisted laser desorption/ionisation quadrupole ion trap mass spectrometryRapid Communications in Mass Spectrometry, 2001
- Electrospray Ionization Ion Mobility SpectrometryAnalytical Chemistry, 1994