Abstract
Spatial encoding in MR techniques is achieved by sampling the signal as a function of time in the presence of a magnetic field gradient. The gradients are assumed to generate a linear magnetic field gradient, and typical image reconstruction relies upon this approximation. However, high-speed gradients in the current generation of MRI scanners often sacrifice linearity for improvements in speed. Such nonlinearity results in distorted images. The problem is presented in terms of first principles, and a correction method based on a gradient field spherical harmonic expansion is proposed. In our case, the amount of distortion measured within a typical field of view (FOV) required for head imaging is sufficiently large that without the use of some distortion correction technique, the images would be of limited use for stereotaxy or longitudinal studies, where precise volumetric information is required. Magn Reson Med 52:115–122, 2004.Keywords
This publication has 18 references indexed in Scilit:
- An image fusion study of the geometric accuracy of magnetic resonance imaging with the Leksell stereotactic localization systemJournal of Applied Clinical Medical Physics, 2001
- An efficient geometric image distortion correction method for a biplanar planar gradient coilMagnetic Resonance Materials in Physics, Biology and Medicine, 2000
- Animal: Validation and Applications of Nonlinear Registration-Based SegmentationInternational Journal of Pattern Recognition and Artificial Intelligence, 1997
- Technical Note. Effect of Geometrical Distortion Correction in MR on Image Registration AccuracyJournal of Computer Assisted Tomography, 1996
- Temporal Spherical-Harmonic Expansion and Compensation of Eddy-Current Fields Produced by Gradient PulsesJournal of Magnetic Resonance, Series A, 1993
- Correction of spatial distortion in magnetic resonance angiography for radiosurgical treatment planning of cerebral arteriovenous malformationsMagnetic Resonance Imaging, 1992
- Analysis of machine-dependent and object-induced geometric distortion in 2DFT MR imagingMagnetic Resonance Imaging, 1992
- A technique for accurate magnetic resonance imaging in the presence of field inhomogeneitiesIEEE Transactions on Medical Imaging, 1992
- Correction of Spatial Distortion in MR ImagingJournal of Computer Assisted Tomography, 1987