Macroscopic Agglutination Test for Rapid Diagnosis of Human Leptospirosis
- 1 November 1998
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 36 (11) , 3138-3142
- https://doi.org/10.1128/jcm.36.11.3138-3142.1998
Abstract
A commercially available slide agglutination test (SAT) for the diagnosis of human leptospirosis was evaluated by comparing it to an immunoglobulin M (IgM) enzyme-linked immunosorbent assay (ELISA) and to the microscopic agglutination test (MAT). For all 108 patients, leptospirosis was diagnosed on the basis of a fourfold or greater increase in titer by MAT (seroconversion), and all but 1 of 245 controls were MAT negative (titers, <1:100). Both SAT and the IgM ELISA failed to detect one case of infection (sensitivity, 99%). Only 3 of 145 blood donors and none of the 100 patients with other illnesses were SAT positive (specificity, 99%). The overall results were similar for the three tests; however, SAT and ELISA were statistically more sensitive as initial screening tests. For 22% of the patients, the diagnosis of leptospirosis was made earlier by SAT than by MAT. SAT detected 27 (44%) of 62 MAT-negative patients with the first serum sample. ELISA and SAT had very similar results. Follow-up of patients for 1 year after the onset of symptoms showed a decreasing rate of positivity by SAT from the third month on. The rate of positivity by ELISA decreased more slowly, to about 67% by the end of the study. By MAT all patients were persistently reactive. SAT and ELISA seem to be convenient methods for the rapid and early screening for leptospirosis and could replace the less sensitive MAT. ELISA gives less subjective results than SAT and provides information on IgM kinetics, but it can be performed only by the more sophisticated laboratories. SAT is inexpensive, can be performed more quickly and more easily than ELISA, and could be used by the less well equipped laboratories.Keywords
This publication has 11 references indexed in Scilit:
- Evaluation of a commercial enzyme-linked immunosorbent assay for detection of immunoglobulin M antibody in diagnosis of human leptospiral infectionJournal of Clinical Microbiology, 1997
- Immunodiagnosis of Human Leptospirosis by Dot-Elisa for the Detection of IgM, IgG, and IgA AntibodiesThe American Journal of Tropical Medicine and Hygiene, 1997
- Behaviour of specific IgM, IgG and IgA class antibodies in human leptospirosis during the acute phase of the disease and during convalescence.1995
- Evaluation of the Immunofluorescent Antibody Test for the Diagnosis of Human LeptospirosisThe American Journal of Tropical Medicine and Hygiene, 1995
- Dot-ELISA-IgM in saliva for the diagnosis of human leptospirosis using polyester fabric-resin as support (Preliminary Report)Revista do Instituto de Medicina Tropical de São Paulo, 1994
- Imunodiagnóstico da leptospirose humana através do teste ELISA-IgM, empregando-se diferentes preparações antigênicas a partir de sorotipos prevalentes de Leptospira interrogansRevista do Instituto de Medicina Tropical de São Paulo, 1990
- The Rapid Diagnosis of Leptospirosis: A Prospective Comparison of the Dot Enzyme-Linked Immunosorbent Assay and the Genus-Specific Microscopic Agglutination Test at Different Stages of IllnessThe Journal of Infectious Diseases, 1988
- Rapid Serodiagnosis of Leptospirosis Using the IgM-Specific Dot-ELISA: Comparison with the Microscopic Agglutination Test *The American Journal of Tropical Medicine and Hygiene, 1985
- Improved microtechnique for the leptospiral microscopic agglutination test.1973
- Improved Microtechnique for the Leptospiral Microscopic Agglutination TestApplied Microbiology, 1973