DNA fingerprinting analysis of coagulase negative staphylococci implicated in catheter related bloodstream infections
Open Access
- 1 November 2002
- journal article
- research article
- Published by BMJ in Journal of Clinical Pathology
- Vol. 55 (11) , 824-828
- https://doi.org/10.1136/jcp.55.11.824
Abstract
Aims: The epidemiological assessment of cases of coagulase negative staphylococcal catheter related bloodstream infection.Methods: Two hundred and thirty patients with suspected catheter related bloodstream infection were evaluated over a two year period. Central venous catheters were cultured both endoluminally and extraluminally. Peripheral blood, catheter hubs, skin entry, and skin control sites were also cultured. Pulsed field gel electrophoresis (PFGE) was used to DNA fingerprint coagulase negative staphylococci isolated from patients with presumptive catheter related bloodstream infection.Results: Sixty cases of catheter related bloodstream infection were identified, 21 of which were attributed to coagulase negative staphylococci. Two hundred and ninety four separate isolates of coagulase negative staphylococci from the 21 cases of catheter related bloodstream infection were subjected to PFGE (mean of 14 for each case). Catheter related bloodstream infection was only confirmed by PFGE analysis in 16 of the 21 cases because in the remaining five cases peripheral blood and central venous catheter coagulase negative staphylococci isolates were different. Skin entry, control skin, and central venous catheter hub isolates matched peripheral blood isolates in six, four, and seven cases, respectively. Coagulase negative staphylococci isolates could not be cultured from the patients’ own skin in seven cases of catheter related bloodstream infection. Central venous catheter lumens were colonised in all cases of catheter related bloodstream infection compared with 44–81% of cases that had positive external surface catheter tip cultures, depending on the threshold used to define significant growth.Conclusions: Catheter related bloodstream infection as a result of coagulase negative staphylococci may be over stated in about a quarter of cases, unless a discriminatory technique is used to fingerprint isolates. No single, simplistic route of bacterial contamination of central venous catheters was identified, but endoluminal catheter colonisation is invariably present in cases of catheter related bloodstream infection.Keywords
This publication has 18 references indexed in Scilit:
- Use of pulsed field gel electrophoresis to determine the source of microbial contamination of central venous cathetersEuropean Journal of Clinical Microbiology & Infectious Diseases, 1998
- Evaluation of a novel endoluminal brush method for in situ diagnosis of catheter related sepsis.Journal of Clinical Pathology, 1997
- Novel approach to investigate a source of microbial contamination of central venous cathetersEuropean Journal of Clinical Microbiology & Infectious Diseases, 1997
- A Clinical Trial on the Prevention of Catheter-Related Sepsis Using a New Hub ModelAnnals of Surgery, 1996
- Methicillin-resistant Staphylococcus haemolyticus on the hands of health care workers: a route of transmission or a source?Journal of Hospital Infection, 1995
- A Prospective Study of the Catheter Hub as the Portal of Entry for Microorganisms Causing Catheter-Related Sepsis in NeonatesThe Journal of Infectious Diseases, 1993
- Evaluation of three methods for culturing long intravascular cathetersJournal of Hospital Infection, 1989
- Outbreak of coagulase negative staphylococcus highly resistant to ciprofloxacin in a leukaemia unit.BMJ, 1989
- Quantitative Culture of Intravenous Catheters and Other Intravascular InsertsThe Journal of Infectious Diseases, 1980
- A Semiquantitative Culture Method for Identifying Intravenous-Catheter-Related InfectionNew England Journal of Medicine, 1977