Comparison of enzyme immunoassays and an immunofluorescence test for detection of antibody to human immunodeficiency virus in African sera
- 1 April 1987
- journal article
- research article
- Published by Springer Nature in European Journal of Clinical Microbiology & Infectious Diseases
- Vol. 6 (2) , 132-135
- https://doi.org/10.1007/bf02018193
Abstract
A total of 152 sera from African subjects were tested for presence of antibody to human immunodeficiency virus using four enzyme immunoassays (EIA) marketed by Abbott Diagnostics, Organon Teknika, Wellcome and Diagnostics Pasteur respectively, an indirect immunofluorescence assay (IFA) and an immunoblot assay (IBA) as reference test. The sensitivity (95 % confidence limits, CL) of the EIAs and the IFA ranged between 80.9 % and 99.1 %. The specificity of the Abbott EIA was lower (95 % CL: 38.1–72 %) than that of the other assays (95 % CL: 83.5–100 %). The use of an IFA or the Wellcome competitive EIA as confirmatory test on initially EIA positive sera yielded a specificity of 85.5–100% (95 % CL) compared with the IBA. The costs of screening by an EIA, followed by confirmatory testing of reactive sera with IFA or the Wellcome EIA and IBA on discrepant test results was similar for all combinations with the exception of initial screening with the Abbott EIA which was more expensive. Using a limited number of sera from African subjects no one test system yielded a significantly superior degree of specificity or sensitivity.Keywords
This publication has 19 references indexed in Scilit:
- AIDS in Africa: An Epidemiologic ParadigmScience, 1986
- BLOOD DONOR SERA WITH FALSE-POSITIVE WESTERN BLOT REACTIONS TO HUMAN IMMUNODEFICIENCY VIRUSThe Lancet, 1986
- EVALUATION OF SIX ENZYME IMMUNOASSAYS FOR ANTIBODY AGAINST HUMAN IMMUNODEFICIENCY VIRUSThe Lancet, 1986
- EVALUATION OF EIGHT ELISA KITS FOR THE DETECTION OF ANTI-LAV/HTLV-III ANTIBODIESThe Lancet, 1986
- AIDS Virus Infection in Nairobi ProstitutesNew England Journal of Medicine, 1986
- ELISA HTLV RETROVIRUS ANTIBODY REACTIVITY ASSOCIATED WITH MALARIA AND IMMUNE COMPLEXES IN HEALTHY AFRICANSThe Lancet, 1985
- Detection of human anti‐HTLV‐III antibodies by indirect immunofluorescence using fixed cellsTransfusion, 1985
- Seroepidemiology of HTLV-III antibodies in a remote population of eastern Zaire.BMJ, 1985
- Evidence for Exposure to HTLV-III in Uganda Before 1973Science, 1985
- Prevalence of Antibodies to Lymphadenopathy-Associated Retrovirus in African Patients with AIDSScience, 1984