Detection of Simulated Candidemia by the BACTEC 9240 System with Plus Aerobic/F and Anaerobic/F Blood Culture Bottles
- 1 October 2003
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 41 (10) , 4714-7
- https://doi.org/10.1128/jcm.41.10.4714-4717.2003
Abstract
We studied the ability of the BACTEC 9240 automated blood culture system to detect simulated candidemia, including both Candida albicans and non- albicans Candida species. Simulated blood cultures were produced using 50 Candida isolates and BACTEC Plus Aerobic/F and Anaerobic/F blood culture bottles. Ten milliliters of blood and a suspension of each isolate containing 1,000 CFU were introduced into each bottle and then incubated at 35°C in the BACTEC 9240 system. The system detected growth in 56 of 100 bottles. Four isolates did not have growth detected in either bottle after 21 days of incubation, resulting in four missed episodes of candidemia. If the blood culture bottles had been incubated for 5 days, an additional episode of candidemia would have remained undetected. If the bottles had been incubated for only 3 days, another episode would have been missed, resulting in up to six missed episodes of candidemia (four Candida glabrata isolates, one C. albicans isolate, and one Candida rugosa isolate). Terminal subculture of bottles without detected growth recovered yeast in 93% (41 of 44) of the bottles, representing 41 false negatives. In bottles where growth was detected, the time to detection was ∼24 h. However, the mean time to growth detection for C. glabrata isolates in anaerobic medium was 22.14 ± 2.47 h, but it was 120.89 ± 35.33 h in aerobic medium ( P < 0.001). The BACTEC 9240 system detected growth of most Candida isolates; however, the delayed time to detection of C. glabrata is clinically significant. Given the high rate of false negatives, terminal subcultures may be helpful in certain situations.Keywords
This publication has 7 references indexed in Scilit:
- Three Days of Incubation May Be Sufficient for Routine Blood Cultures with BacT/Alert FAN Blood Culture BottlesJournal of Clinical Microbiology, 2001
- Value of terminal subculture of automated blood cultures in patients with candidaemia.European Journal of Clinical Microbiology & Infectious Diseases, 2000
- National Epidemiology of Mycoses Survey (NEMIS): Variations in Rates of Bloodstream Infections Due to Candida Species in Seven Surgical Intensive Care Units and Six Neonatal Intensive Care UnitsClinical Infectious Diseases, 1999
- Nosocomial Bloodstream Infections in United States Hospitals: A Three‐Year AnalysisClinical Infectious Diseases, 1999
- Use of simulated blood cultures to compare a specific fungal medium with a standard microorganism medium for yeast detectionEuropean Journal of Clinical Microbiology & Infectious Diseases, 1998
- Controlled clinical laboratory comparison of BACTEC plus aerobic/F resin medium with BacT/Alert aerobic FAN medium for detection of bacteremia and fungemiaJournal of Clinical Microbiology, 1997
- Secular Trends in the Epidemiology of Nosocomial Fungal Infections in the United States, 1980-1990The Journal of Infectious Diseases, 1993