Clinical evaluation of the Holladay and SRK II formulas
- 1 January 1990
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 16 (1) , 71-74
- https://doi.org/10.1016/s0886-3350(13)80877-2
Abstract
We compared the accuracy of the Holladay and SRK IITM intraocular lens power calculation formulas with that of two commonly used formulas, the Binkhorst and SRK. We found no significant difference between the accuracy of the four formulas in cases of posterior chamber lens implanation. For anterior chamber lenses, the SRK II formula was significantly less accurate than the other three formulas in eyes with long axial length.This publication has 3 references indexed in Scilit:
- Comparison of the SRK II™ formula and other second generation formulasJournal of Cataract & Refractive Surgery, 1988
- A three-part system for refining intraocular lens power calculationsJournal of Cataract & Refractive Surgery, 1988
- Clinical evaluation of six intraocular lens calculation formulasAmerican Intra-Ocular Implant Society Journal, 1985