Ambulatory monitoring of the impedance cardiogram
- 1 March 1996
- journal article
- clinical trial
- Published by Wiley in Psychophysiology
- Vol. 33 (2) , 184-193
- https://doi.org/10.1111/j.1469-8986.1996.tb02122.x
Abstract
The growing need for more advanced ambulatory monitoring has led to the development of an ambulatory monitor for impedance cardiography (VU-AMD). This paper presents two studies addressing the validity of the VU-AMD. In the first study, the cardiovascular responses of 25 subjects during various conditions were simultaneously recorded with the VU-AMD and a standard laboratory impedance device. Correlations between the responses of the ambulatory and laboratory devices were high, both inter- and intraindividually, except for stroke volume and cardiac output during exercise. In the second study, 26 subjects underwent 24-hr monitoring with the VU-AMD. The values obtained with the VU-AMD were realistic and varied in a predictable way over activity and posture. It is concluded that the VU-AMD is a valid device for the measurement of systolic time intervals in real-life situations, but its applicability for absolute stroke volume and cardiac output determination remains to be established.Keywords
This publication has 29 references indexed in Scilit:
- Impedance cardiography: The failure of sternal electrodes to predict changes in stroke volumeBiological Psychology, 1993
- Signal fidelity requirements for deriving impedance cardiographie measures of cardiac function over a broad heart rate rangeBiological Psychology, 1993
- Postural stability of hemodynamic responses during mental challengePsychophysiology, 1993
- Comparison of Impedance Cardiographic Measurements using Band and Spot ElectrodesPsychophysiology, 1992
- Comparison of Spot and Band Impedance Cardiogram Electrodes across Different TasksPsychophysiology, 1989
- Evaluation of Beta‐Adrenergic Influences on Cardiovascular and Metabolic Adjustments to Physical and Psychological StressPsychophysiology, 1986
- Continuous noninvasive monitoring of left ventricular function during exercise by thoracic impedance cardiography-automated derivation of systolic time intervalsAmerican Heart Journal, 1982
- Pre‐ejection Period: Measuring Beta‐adrenergic Influences Upon the HeartPsychophysiology, 1979
- Computerized system for noninvasive techniques: I. its value for systolic time intervalsThe American Journal of Cardiology, 1974
- Effects of Adrenergic Receptor Activation and Blockade on the Systolic Preejection Period, Heart Rate, and Arterial Pressure in ManJournal of Clinical Investigation, 1967