Subnanomolar determination of a beryllium ion by a novel Be(II) microsensor based on 4-nitrobenzo-9-crown-3-ether
- 2 July 2008
- journal article
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 63 (7) , 684-689
- https://doi.org/10.1134/s1061934808070149
Abstract
In this work, for the first time, we introduce a highly selective and sensitive Be(II) microsensor. 4-nitrobenzo-9-crown-3-ether (NBCE) was used as a membrane-active component to prepare a Be(II)-selective polymeric membrane microelectrode. The electrode exhibits a Nernstian response toward Be(II) ions over a very wide concentration range (1.0 × 10−4–1.0 × 10−10 M), with a detection limit of 3.5 × 10−11 M (∼350 pg/L). In fact, the electrode presents a fast response time in the whole concentration range (6 s). The proposed microelectrode can be used for at least six weeks without any considerable divergence in the potentials. The proposed membrane sensor revealed a selectivity toward Be(II) ions over a wide variety of other metal ions including common alkali, alkaline-earth, and rare-earth ions. It could be used in the pH range of 3.0–11.5. The microelectrode was successfully used as an indicator electrode for the titration of 20 mL of 1.0 × 10−6 M Be2+ solution with 1.0 × 10−4 M of EDTA. It was also applied to the direct determination of beryllium ions in beryl and binary mixtures.Keywords
This publication has 33 references indexed in Scilit:
- Zn2+PVC-based Membrane Sensor Based on 3-[(2-Furylmethylene)amino]-2-thioxo-1,3-thiazolidin-4-oneBulletin of the Korean Chemical Society, 2005
- Sub-micro level monitoring of beryllium ions with a novel beryllium sensor based on 2,6-diphenyl-4-benzo-9-crown-3-pyridineTalanta, 2004
- NOVEL Be(II) MEMBRANE ELECTRODE-BASED ON A DERIVATIVE OF BENZO-9-CROWN-3Main Group Metal Chemistry, 2002
- Utilization of solid phase spectrophotometry for determination of trace amounts of beryllium in natural waterAnalytica Chimica Acta, 2001
- Beryllium-selective membrane sensor based on 3,4-di[2-(2-tetrahydro-2H-pyranoxy)]ethoxy styrene–styrene copolymerAnalytica Chimica Acta, 2001
- Highly sensitive beryllium detection with microwave plasma source atomic emission spectrometryAnalytica Chimica Acta, 2000
- Beryllium RevisitedJournal of Occupational and Environmental Medicine, 1997
- Lipophilic and immobilized anionic additives in solvent polymeric membranes of cation-selective chemical sensorsAnalytica Chimica Acta, 1993
- Macrocycle-Facilitated Transport of Ions in Liquid Membrane SystemsSeparation and Purification Methods, 1986
- Lipophilic salts as membrane additives and their influence on the properties of macro- and micro-electrodes based on neutral carriersAnalytica Chimica Acta, 1985