Airway Retention of Materials of Different Solubility following Local Intrabronchial Deposition in Dogs
- 1 June 2003
- journal article
- Published by Mary Ann Liebert Inc in Journal of Aerosol Medicine
- Vol. 16 (2) , 153-166
- https://doi.org/10.1089/089426803321919915
Abstract
We used a gamma camera to monitor the retention and clearance of radiolabeled human serum albumin (HSA), a water-soluble material with molecular weight of 66,000 Daltons, and radiolabeled sulfur colloid (SC), an insoluble submicron (0.22 microm) particle, following localized deposition in a 4-5-mm bronchus in each of five dogs. The average retention time of HSA was significantly greater than that of SC both in the deposition site (23.3 +/- 2.3 vs. 18.2 +/- 2.9 min respectively, p < 0.05) and in the clearance pathway (26.5 +/- 2.0 vs. 22.0 +/- 1.4 min, respectively, p < 0.05). The mean percent retention at the deposition site at 60 minutes post-deposition also was significantly greater for HSA than for SC (33.5 +/- 10.1 vs. 11.6 +/- 4.7%, respectively, p < 0.05). The percentage of HSA which had cleared to the level of the cuffed endotracheal tube was significantly less than that of SC (18.0 +/- 6.7 vs. 35.8 +/- 3.5%, respectively, p < 0.05) at 60 min post-deposition. These findings indicate that a low-permeating water-soluble material such as HSA deposited on the surface of an airway remains in contact with the sensitive airway epithelium to a greater extent than does a solid insoluble particle. Based on our results, we speculate that the slower clearance of HSA compared to SC was likely due to diffusion of a greater portion of the HSA into the periciliary sol layer which may be transported less efficiently than the mucus layer during mucociliary clearance. Additionally, some degree of uptake of HSA by bronchial epithelium may have contributed to its increased retention.Keywords
This publication has 33 references indexed in Scilit:
- Pulmonary sup 99m Tc-human serum albumin clearance and effects of surfactant replacement after lung lavage in rabbitsCritical Care Medicine, 1996
- A Microspray Nozzle for Local Administration of Liquids or Suspensions to Lung Airways via BronchoscopyJournal of Aerosol Medicine, 1993
- Pulmonary Clearance of Inhaled Particles 24 to 48 Hours Post Deposition: Effect of Beta-Adrenergic StimulationJournal of Aerosol Medicine, 1993
- A Pilot Study of Aerosolized Amiloride for the Treatment of Lung Disease in Cystic FibrosisNew England Journal of Medicine, 1990
- Normal values for quantitative parameters for evaluation of mucociliary clearance in lungs.The Tohoku Journal of Experimental Medicine, 1989
- Measurement of rotational temperature and dissociation in N2O glow discharges using i n s i t u Fourier transform infrared spectroscopyJournal of Applied Physics, 1988
- Relative permeability of nasal, tracheal, and bronchoalveolar mucosa to macromolecules in rats exposed to ozoneJournal of Toxicology and Environmental Health, 1986
- Regional Mucociliary Removal of Inhaled Particles in Smokers with Small Airways DiseaseRespiration, 1983
- The localisation of particles retained in the trachea of the ratThe Journal of Pathology, 1980
- Halothane Depresses Mucociliary Flow in the TracheaAnesthesiology, 1976