Reproducibility of cardiovascular, respiratory, and metabolic responses to submaximal exercise: The HERITAGE Family Study
- 1 February 1998
- journal article
- research article
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 30 (2) , 259-265
- https://doi.org/10.1097/00005768-199802000-00014
Abstract
This study determined the reproducibility of cardiovascular, respiratory, and metabolic responses to submaximal cycle ergometer exercise at two power outputs (50 W and 60% ˙VO2max) on each of two separate days in a sample of 390 subjects (198 men and 192 women) participating in the HERITAGE Family Study. The same protocol was conducted across 3 d in an intracenter quality control substudy which included an additional 55 subjects. Reproducibility estimates included technical error, coefficient of variation, and intraclass correlation for each of the selected variables for both subject populations. Further, since the data were collected across four clinical centers, intraclass correlations were also computed separately by clinical center. Most variables were highly reproducible, with coefficients of variation below 9% and intraclass correlations over 0.80. These results were consistent for both subject populations and across all four clinical centers. Reproducibility indicators were generally better at the higher power output. It is concluded that within-subject day-to-day variation and measurement unreliabilities are generally small compared with the between-subject variance in the response to submaximal exercise at each of the clinical centers of the HERITAGE Family Study.Keywords
This publication has 17 references indexed in Scilit:
- The HERITAGE Family Study: Quality assurance and quality controlAnnals of Epidemiology, 1996
- Aims, design, and measurement protocolMedicine & Science in Sports & Exercise, 1995
- Reliability and Within Subject Variability of V̇E, V̇O2, Heart Rate and Blood Pressure During Submaximum Cycle ErgometryInternational Journal of Sports Medicine, 1993
- The consistency of cardiac output measurement (CO2 rebreathe) in children during exerciseEuropean Journal of Applied Physiology, 1982
- Biological variability in maximum aerobic powerMedicine & Science in Sports & Exercise, 1982
- Reliability of the cardiac output measurement with the indirect Fick-principle for CO2 during exercisePflügers Archiv - European Journal of Physiology, 1980
- Intraclass correlations: Uses in assessing rater reliability.Psychological Bulletin, 1979
- THE PHYSIOLOGICAL MEANING OF THE MAXIMAL OXYGEN INTAKE TEST1Journal of Clinical Investigation, 1958
- Determination of Mixed Venous CO2 Tensions by RebreathingJournal of Applied Physiology, 1956
- SOME PROPERTIES OF MAXIMAL AND SUBMAXIMAL EXERCISE WITH REFERENCE TO PHYSIOLOGICAL VARIATION AND THE MEASUREMENT OF EXERCISE TOLERANCEAmerican Journal of Physiology-Legacy Content, 1944