Trunk Extensor and Flexor Strength Measured by the Cybex 6000 Dynamometer
- 1 December 1996
- journal article
- Published by Wolters Kluwer Health in Spine
- Vol. 21 (23) , 2770-2776
- https://doi.org/10.1097/00007632-199612010-00012
Abstract
Isokinetic trunk extensor and flexor strength (peak torque, total work, power acceleration time, and torque acceleration energy) at 30 degrees/sec, 120 degrees/sec, and 180 degrees/sec and isometric extensor and flexor peak torque were measured in 24 healthy women. Measurements were performed in three separate sessions at the same time of day and by the same experienced examiner. The number of days between Session 1 and Session 2 and between Session 1 and Session 3 ranged from 1 to 7 (median, 2 days) and from 23 to 48 (median, 32 days), respectively. The test results were not revealed before all sessions were completed. To determine the intrasession, short-term, and long-term reproducibility of several trunk strength variables measured by the Cybex 6000 isokinetic dynamometer (Lumex, Inc., Ronkonkoma, NY). Only few and insufficient data regarding the reproducibility of trunk strength measurements exist. Previous studies have focused on coefficients of correlation to express reproducibility. Correlations, however, are misleading and inappropriate for this purpose. The critical difference is the difference between two results that would be statistically significant when applied to a reference group in steady state. The critical difference in percentage is calculated as 2.77 X coefficient of variation (%). Isokinetic dynamometry (Cybex 6000). Reproducibility was expressed as pooled coefficients of variation, individual coefficients of variation, and critical differences. Substantial between-subject variation of coefficients of variation was found for all strength variables; for example, the 80% central range for individual coefficients of variation for long-term reproducibility of extensor strength measurements at 30 degrees/sec ranged from 2.5% to 19.5%. Critical differences calculated using the pooled variances for long-term reproducibility were higher than 20% for all measures, mounting to 80% for acceleration time. Strength testing is of limited value in the individual subject because of considerable day-to-day variability. This finding has important clinical implications.Keywords
This publication has 32 references indexed in Scilit:
- Accurate assessment of precision errors: How to measure the reproducibility of bone densitometry techniquesOsteoporosis International, 1995
- Distinguishable Groups of Musculoskeletal Low Back Pain Patients and Asymptomatic Control Subjects Based on Physical Measures of the NIOSH Low Back AtlasSpine, 1994
- Trunk Strength Testing with Iso-MachinesSpine, 1993
- Reproducibility of Trunk Isoinertial Dynamic Performance in Patients with Low Back PainPublished by Wolters Kluwer Health ,1992
- MonitoringScandinavian Journal of Clinical and Laboratory Investigation, 1992
- A New Robust Index for Measuring Isokinetic Trunk Flexion and ExtensionSpine, 1991
- Reliability of Isokinetic Measurements of Trunk Muscle PerformanceSpine, 1991
- Isokinetic Trunk and Lifting Strength Measurements: Variability as an Indicator of EffortSpine, 1988
- Repeatability of phasic muscle activity: Performance of surface and intramuscular wire electrodes in gait analysisJournal of Orthopaedic Research, 1985