Fifteen-Year Experience with 1678 Hancock Porcine Bioprosthetic Heart Valve Replacements
- 1 October 1989
- journal article
- research article
- Published by Wolters Kluwer Health in Annals of Surgery
- Vol. 210 (4) , 435-443
- https://doi.org/10.1097/00000658-198910000-00003
Abstract
The Hancock porcine valve was the first commercially available biologic heart valve and has been in continuous use at the Brigham and Women''s Hospital [Boston, Massachusetts, USA], since January 1972. Through December 1987 we implanted 1678 valves in 1533 patients (885 male; 648 female; 17 to 95 years of age, with a mean of 60 years). There were 825 aortic valve replacements (AVR), 562 isolated mitral valve replacements (MVR), and 146 aortic mitral replacements (DVR). Ninety-four per cent of the patients were functional class III or IV. Associated coronary bypass was done in 25% of patients. Four per cent of patients were lost to follow up during a 1- to 16-year period with a mean of 6 years. Morbidity and mortality rates on a actuarial basis were calculated 10 and 15 years after operation for AVR, MVR, and DVR. The data indicates that the probability of reoperation for structural valve failure is quite reasonable as of 10 years, but from 10 to 15 years the numbers sharply fall off so that the probable effective life of the valve is 10 years. However in the elderly age group (equal to or greater than 70 years of age) the incidence of structural valve degeneration is markedly diminished, making this an ideal valve substitute for the elderly. It is also an ideal valve substitute in any patient who had a contraindication to long-term anticoagulation because of current medical or surgical problems.This publication has 20 references indexed in Scilit:
- Performance of the Hancock Porcine Bioprosthesis Following Aortic Valve Replacement: Considerations Based on a 15-Year ExperienceThe Annals of Thoracic Surgery, 1988
- Incidence of Primary Tissue Valve Failure in Porcine Bioprosthetic Heart ValvesThe Annals of Thoracic Surgery, 1988
- Thromboembolic Complications of Current Cardiac Valvular ProsthesesThe Annals of Thoracic Surgery, 1982
- Five to Eight-Year Follow-up of Patients Undergoing Porcine Heart-Valve ReplacementNew England Journal of Medicine, 1981
- Long-term evaluation of the porcine xenograft bioprosthesisThe Journal of Thoracic and Cardiovascular Surgery, 1979
- Biological factors affecting long-term results of valvular heterograftsThe Journal of Thoracic and Cardiovascular Surgery, 1969
- HETEROLOGOUS AORTIC-VALVE TRANSPLANTATION IN THE DOGThe Lancet, 1965
- Homograft Aortic Valve Replacement in Aortic Incompetence and StenosisThorax, 1964
- HOMOGRAFT REPLACEMENT OF THE AORTIC VALVEThe Lancet, 1962
- Mitral ReplacementAnnals of Surgery, 1961