A Novel, Self-Expanding, Nitinol Stent in Medically Refractory Intracranial Atherosclerotic Stenoses
Top Cited Papers
- 1 May 2007
- journal article
- research article
- Published by Wolters Kluwer Health in Stroke
- Vol. 38 (5) , 1531-1537
- https://doi.org/10.1161/strokeaha.106.477711
Abstract
Background and Purpose— The purpose of this study was to assess the safety and performance of the Wingspan stent system and Gateway percutaneous transluminal angioplasty balloon catheter in the treatment of high-grade, intracranial atherosclerotic lesions in patients who had failed medical therapy. Methods— In this prospective, multicenter, single-arm study, medically refractory patients with a modified Rankin score ≤3 and recurrent symptoms attributable to angiographically demonstrated intracranial stenosis ≥50% in a vessel 2.5 to 4.5 mm in diameter were enrolled. Intracranial lesions were predilated with an undersized Gateway balloon catheter to 80% of the native vessel diameter, followed by deployment of the self-expanding Wingspan stent to facilitate further remodeling of the atherosclerotic plaque and to maintain vessel patency. Neurologic examinations and angiograms were performed at 6 months after the procedure. Results— Among the 45 patients enrolled, the degree of stenosis was reduced from a baseline of 74.9±9.8% to 31.9±13.6% after stenting and 28±23.2% at the 6-month follow-up. The 30-day composite ipsilateral stroke/death rate was 4.5% (2/44); at the 6-month follow-up, the ipsilateral stroke/death rate was 7.0%, the rate for all strokes was 9.7%, and all-cause mortality was 2.3%. Physician-reported follow-up in 43 patients (average of 13 months) conducted outside the study protocol (not adjudicated by the clinical event committee) reported 1 additional ipsilateral stroke. Conclusions— In medically refractory patients with high-grade intracranial atherosclerotic stenoses, a new treatment paradigm involving predilation with an undersized Gateway percutaneous transluminal angioplasty balloon catheter and placement of a self-expanding Wingspan stent system appears to be safe, may facilitate remodeling, and may contribute to favorable angiographic outcomes.Keywords
This publication has 14 references indexed in Scilit:
- Angioplasty for Symptomatic Intracranial StenosisStroke, 2006
- Predictors of Ischemic Stroke in the Territory of a Symptomatic Intracranial Arterial StenosisCirculation, 2006
- Comparison of Warfarin and Aspirin for Symptomatic Intracranial Arterial StenosisNew England Journal of Medicine, 2005
- Stenting of Symptomatic Atherosclerotic Lesions in the Vertebral or Intracranial Arteries (SSYLVIA)Stroke, 2004
- Angioplasty for Intracranial Symptomatic Vertebrobasilar IschemiaNeurosurgery, 2002
- Percutaneous transluminal angioplasty for intracranial atherosclerotic lesions: evolution of technique and short-term resultsJournal of Neurosurgery, 1999
- Benefit of Carotid Endarterectomy in Patients with Symptomatic Moderate or Severe StenosisNew England Journal of Medicine, 1998
- Transluminal angioplasty for arteriosclerotic disease of the distal vertebral and basilar arteries.Journal of Neurology, Neurosurgery & Psychiatry, 1996
- Percutaneous transluminal angioplasty in the treatment of atherosclerotic disease of the anterior cerebral circulation and hemodynamic evaluationJournal of Neurosurgery, 1995
- Beneficial Effect of Carotid Endarterectomy in Symptomatic Patients with High-Grade Carotid StenosisNew England Journal of Medicine, 1991