Comparison of radioimmunoassay and enzyme immunoassay methods in determining gentamicin pharmacokinetic parameters and dosages
- 1 October 1982
- journal article
- research article
- Published by American Society for Microbiology in Antimicrobial Agents and Chemotherapy
- Vol. 22 (4) , 648-651
- https://doi.org/10.1128/aac.22.4.648
Abstract
Radioimmunoassay and enzyme immunoassay methods for analysis of serum gentamicin levels have been shown to be comparable. The purpose of this study was to determine if serum concentration-time data from the same patient assayed by radioimmunoassay and enzyme immunoassay would provide the same estimates for half-life, elimination rate constant, distribution volume, drug clearance, and gentamicin dose. A total of 103 pre- and postinfusion serum samples were obtained from 32 patients. The samples were divided and assayed by radioimmunoassay and enzyme immunoassay. Serum concentration-time data were fitted to a one-compartment model, and kinetic calculations were performed using the method of Sawchuk et al. (Clin. Pharmacol. Ther. 21:362-369, 1977). While good correlation was established between the two assay methods, significant (P less than 0.05) mean differences were seen in distribution volume (25%), gentamicin clearance (15%), and half-life (11%), using the quantitative data from both methods. Because of differences noted in these pharmacokinetic parameters, significant differences were also noted in dosage calculations. We conclude that there are differences in the pharmacokinetic parameters obtained using results from the radioimmunoassay and enzyme immunoassay. These differences also translate into significant differences between dosage recommendations when individualization of the gentamicin regimen is attempted.This publication has 10 references indexed in Scilit:
- Gentamicin pharmacokinetics in 1,640 patients: method for control of serum concentrationsAntimicrobial Agents and Chemotherapy, 1982
- Serum Aminoglycoside Assay by Enzyme-Mediated Immunoassay (EMIT): Correlation with Radioimmunoassay, Fluoroimmunoassay, and Acetyltransferase and Microbiological AssaysAntimicrobial Agents and Chemotherapy, 1981
- Comparison of five methods for the assay of serum gentamicinAntimicrobial Agents and Chemotherapy, 1981
- Rapid, Simple Enzyme Immunoassay for GentamicinAntimicrobial Agents and Chemotherapy, 1979
- Ecthyma GangrenosumArchives of Surgery, 1979
- Enzyme immunoassay for gentamicin.Clinical Chemistry, 1978
- Kinetic model for gentamicin dosing with the use of individual patient parametersClinical Pharmacology & Therapeutics, 1977
- Simultaneous antibiotic levels in “breakthrough” gram-negative rod bacteremiaThe American Journal of Medicine, 1976
- Gentamicin Blood Levels: a Guide to NephrotoxicityAntimicrobial Agents and Chemotherapy, 1975
- Experience in Monitoring Gentamicin Therapy during Treatment of Serious Gram-Negative SepsisBMJ, 1974