Patients are exposed to X rays when undergoing medical examinations in diagnostic radiology. Exposure data acquired and assessed in Germany for the year 1997 resulted in a mean annual effective dose of 2 ± 0.5 mSv per head of the population, thereby reaching or exceeding the average level of environmental radiation in many cases. The underlying frequency of medical X-ray examinations was ≈136 million, i.e. ≈1.7 examinations annually per head of the population. For comparison, corresponding data of other countries were extracted from the UNSCEAR 2000 report or originate from the literature. Data analysis shows significant differences in national radiological practices and a very uneven distribution of patient doses amongst the world population. The mean annual effective dose per head of the population varies by up to a factor of 60 between health care level I and IV countries, and still by a factor of ≈6 within health care level I countries. While projection radiography has succeeded in reducing dose consumption, computed tomography and radiological interventions have given rise to a significant growth of patient exposure, and interventional radiology can even exceed thresholds for deterministic radiation effects. Patient exposure is further shown to result from misadministration and retakes of X-ray examinations, usually not registered, as well as from technical failures of X-ray facilities, which can cause significantly enhanced exposure times. Corresponding data are presented and comments are made on the international situation of non-harmonised data collection on patient exposure as well as of parameters affecting the assessment of exposure and risk.Keywords
This publication has 31 references indexed in Scilit:
- Central dose data management and analysis in IT-driven radiation protection strategiesRadiation Protection Dosimetry, 2005
- Reduction of anatomical noise in medical X-ray imagesRadiation Protection Dosimetry, 2005
- Radiation protection dosimetry for diagnostic radiology patientsRadiation Protection Dosimetry, 2004
- Spectra of scattered photons in large absorbers and their importance for the values of radiation weighting factor wRRadiation Protection Dosimetry, 2004
- Sustainability of medical imagingBMJ, 2004
- Effect of low doses of ionising radiation in infancy on cognitive function in adulthood: Swedish population based cohort studyBMJ, 2004
- Organ dose conversion coefficients for external photon irradiation of male and female voxel modelsPhysics in Medicine & Biology, 2002
- The GSF family of voxel phantomsPhysics in Medicine & Biology, 2001
- Radiation-Induced Skin Injuries and FluoroscopyAmerican Journal of Roentgenology, 2001
- Effective dose ? how effective for patients?Radiation and Environmental Biophysics, 1993