Functional magnetic resonance imaging of the human brain based on signal enhancement by extravascular protons (SEEP fMRI)
- 18 March 2003
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 49 (3) , 433-439
- https://doi.org/10.1002/mrm.10831
Abstract
Functional magnetic resonance imaging (fMRI) studies of the human brain were carried out at 3 Tesla to investigate an fMRI contrast mechanism that does not arise from the blood oxygen‐level dependent (BOLD) effect. This contrast mechanism, signal enhancement by extravascular protons (SEEP), involves only proton‐density changes and was recently demonstrated to contribute to fMRI signal changes in the spinal cord. In the present study it is hypothesized that SEEP fMRI can be used to identify areas of neuronal activity in the brain with as much sensitivity and precision as can be achieved with BOLD fMRI. A detailed analysis of the areas of activity, signal intensity time courses, and the contrast‐to‐noise ratio (CNR), is also presented and compared with the BOLD fMRI results. Experiments were carried out with subjects performing a simple finger‐touching task, or observing an alternating checkerboard pattern. Data were acquired using a conventional BOLD fMRI method (gradient‐echo (GE) EPI, TE = 30 ms), a conventional method with reduced BOLD sensitivity (GE‐EPI, TE = 12 ms), and SEEP fMRI (spin‐echo (SE) EPI, TE = 22 ms). The results of this study demonstrate that SEEP fMRI may provide better spatial localization of areas of neuronal activity, and a higher CNR than conventional BOLD fMRI, and has the added benefit of lower sensitivity to field inhomogeneities. Magn Reson Med 49:433–439, 2003.Keywords
This publication has 12 references indexed in Scilit:
- Extravascular proton‐density changes as a non‐BOLD component of contrast in fMRI of the human spinal cordMagnetic Resonance in Medicine, 2002
- High‐resolution fMRI using multislice partial k‐space GR‐EPI with cubic voxelsMagnetic Resonance in Medicine, 2001
- Spin-echo versus gradient-echo fMRI with short echo timesMagnetic Resonance Imaging, 2001
- Characterization of contrast changes in functional MRI of the human spinal cord at 1.5 TMagnetic Resonance Imaging, 2001
- Single-shot halfk-space high-resolution gradient-recalled EPI for fMRI at 3 teslaMagnetic Resonance in Medicine, 1998
- Cerebral [15O] Water Clearance in Humans Determined by Positron Emission Tomography: II. Vascular Responses to Vibrotactile StimulationJournal of Cerebral Blood Flow & Metabolism, 1997
- Cerebral [15O]Water Clearance in Humans Determined by PET: I. Theory and Normal ValuesJournal of Cerebral Blood Flow & Metabolism, 1996
- Functional Imaging of the Brain by Nuclear Magnetic ResonancePublished by Elsevier ,1994
- Analysis of functional MRI time‐seriesHuman Brain Mapping, 1994
- 4 Tesla gradient recalled echo characteristics of photic stimulation‐induced signal changes in the human primary visual cortexMagnetic Resonance in Medicine, 1993