Evaluation of Biexponential Relaxation Processes by Magnetic Resonance Imaging
- 1 July 1988
- journal article
- research article
- Published by SAGE Publications in Acta Radiologica
- Vol. 29 (4) , 473-479
- https://doi.org/10.1177/028418518802900418
Abstract
Despite the complexity of biologic tissues, a monoexponential behaviour is usually assumed when estimating relaxation processes in vivo by magnetic resonance imaging (MRI). This study was designed to evaluate the potential of biexponential decomposition of T1 and T2 relaxation curves obtained at 1.5 tesla (T). Measurements were performed on a phantom of bicompartmental perspex boxes with combinations of different CuSO4 concentrations. T1 determination was based on a 12-points partial saturation inversion recovery pulse sequence. T2 determination was provided by a multiple spin echo sequence with 32 echoes. Applying biexponential curve analysis, a significant deviation from a monoexponential behaviour was recognized at a ratio of corresponding relaxation rates of about 3 and 2, estimating T1 and T2 relaxation, respectively (p<0.01, F-test). Requiring an SD≤10 per cent for each set of parameters, the biexponential model was accepted when this ratio exceeded a factor of 5 and 8, respectively. Referring to ‘expected’ T1 and T2 values, however, an accuracy within 20 per cent only was observed at ratios of at least 6 and 15. It is concluded that quantitative estimation of individual and specific relaxation components in complex biologic tissues by MRI may prove very difficult.Keywords
This publication has 20 references indexed in Scilit:
- In vitroprotonT1andT2studies on rat liver: Analysis of multiexponential relaxation processesMagnetic Resonance in Medicine, 1986
- Multiple‐spin‐echo imaging with a 2D Fourier methodMagnetic Resonance in Medicine, 1986
- Reducing motion artifacts in two-dimensional Fourier transform imagingMagnetic Resonance Imaging, 1986
- Analysis of multiple T2 proton relaxation processes in human head and imaging on the basis of selective and assigned T2 valuesMagnetic Resonance in Medicine, 1984
- Multi-exponential water proton spin-lattice relaxation in biological tissues and its implications for quantitative NMR imagingPhysics in Medicine & Biology, 1984
- Multiple NMR T2 relaxation values in human liver tissueAmerican Journal of Roentgenology, 1983
- Nuclear Magnetic Resonance and Detection of Human Breast TumorsJNCI Journal of the National Cancer Institute, 1978
- NMR relaxation behavior in living and ischemically damaged tissueMedical Physics, 1976
- The quantitative limitations of exponential curve fittingPhysics in Medicine & Biology, 1971
- Nuclear InductionPhysical Review B, 1946