A highly automated 96‐well solid phase extraction and liquid chromatography/tandem mass spectrometry method for the determination of fentanyl in human plasma
- 7 March 2001
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 15 (7) , 466-476
- https://doi.org/10.1002/rcm.255
Abstract
A high‐throughput bioanalytical method based on automated sample transfer, automated solid phase extraction, and fast liquid chromatography/tandem mass spectrometry (LC/MS/MS) analysis, has been developed for the determination of the analgesic fentanyl in human plasma. Samples were transferred into 96‐well plates using an automated sample handling system. Automated solid phase extraction (SPE) was carried out using a 96‐channel programmable liquid‐handling workstation using a mixed‐mode sorbent. The extracted samples were then dried down, reconstituted and injected onto a silica column using an aqueous/organic mobile phase with tandem mass spectrometric detection. The method has been validated over the concentration range 0.05–100 ng/mL fentanyl in human plasma, based on a 0.25‐mL sample size. The assay is sensitive, specific and robust. More than 2000 samples have been analyzed using this method. The automation of the sample preparation steps not only increased the analysis throughput, but also facilitated the transfer of the method between different bioanalytical laboratories of the same organization. Copyright© 2001 John Wiley & Sons, Ltd.Keywords
This publication has 27 references indexed in Scilit:
- Liquid-liquid extraction using 96-well plate format in conjunction with liquid chromatography/tandem mass spectrometry for quantitative determination of methylphenidate (Ritalin ) in human plasmaRapid Communications in Mass Spectrometry, 2000
- Automated 96-Well SPE and LC−MS−MS for Determination of Protease Inhibitors in Plasma and Cartilage TissuesAnalytical Chemistry, 2000
- High throughput liquid chromatography/mass spectrometry bioanalysis using 96-well disk solid phase extraction plate for the sample preparationRapid Communications in Mass Spectrometry, 1998
- Automated sample preparation using membrane microtiter extraction for bioanalytical mass spectrometryRapid Communications in Mass Spectrometry, 1997
- Determination of subnanogram concentrations of fentanyl in plasma by gas chromatography—mass spectrometry: Comparison with standard radioimmunoassayJournal of Chromatography B: Biomedical Sciences and Applications, 1997
- The Use of Automated Solid Phase Extraction in the '96 well' Format for High Throughput Bioanalysis using Liquid Chromatography Coupled to Tandem Mass SpectrometryRapid Communications in Mass Spectrometry, 1996
- Tissue distribution of fentanyl and alfentanil in the rat cannot be described by a blood flow limited modelJournal of Pharmacokinetics and Biopharmaceutics, 1993
- Determination of fentanyl and alfentanil in plasma by high-performance liquid chromatography with ultraviolet detectionJournal of Chromatography B: Biomedical Sciences and Applications, 1987
- Assay Methods for Fentanyl in SerumAnesthesiology, 1987
- Optimization of the Radioimmunoassays for Measuring Fentanyl and Alfentanil in Human SerumAnesthesiology, 1984