Pharmacokinetics / bioavailability of colchicine in healthy male volunteers
- 1 October 1989
- journal article
- research article
- Published by Springer Nature in European Journal of Drug Metabolism and Pharmacokinetics
- Vol. 14 (4) , 317-322
- https://doi.org/10.1007/bf03190118
Abstract
In a randomized 2-way cross-over study with twelve healthy male volunteers, two colchicine preparations (tablets, A vs. oral solution, B) were tested. The preparations were administered as single doses of 1 mg; prior to and up to 72 h after medication blood samples were collected and the plasma colchicine concentrations determined. Additionally urine samples were collected at 0–2, 2–4, 4–6, 6–8, 8–10, 10–24, 24–48, 48–72 and 72–96 h intervals. The colchicine plasma and urine concentrations were determined by a newly developed and validated RIA method. The mean area under the plasma concentration-time curve (AUC-1, AUC-3) was calculated as 23.95±12.10 (AUC-1) and 26.73±12.75 (AUC-3) h.ng/ml after application of A and 28.01±14.74 (AUC-1) and 31.57+16.58 (AUC-3) h.ng/ml after application of B, respectively. Mean peak plasma concentrations of 4.15±2.35 (A) and 4.88±3.90 (B) ng/ml were reached at 1.15±0.38 (A) and 1.13±0.42 (B) h after application. The mean terminal half-lives accounted for 9.31±3.98 (A) and 10.57±5.53 (B) h. The mean total clearance (Cl/F) and volume of distribution (V/F) were found to be 40.12±20.87 (A) and 46.58±24.65 (B) 1/h and 472.59±196.46 (A) and 624.89±304.09 (B) 1, respectively. The mean total amount excreted in urine (Ae) was 172.66±91.51 (A) and 174.85±63.53 (B) ug. The statistical evaluations of the pharmacokinetic parameters showed no significant differences, either for the extent of absorption (as indicated by the AUQ, or for the rate of absorption (as indicated by Cmax and tmax) between both preparations. The relative bioavailability (assuming the solution to be 100%) accounted for 115% (AUC-1) and 114% (AUC-3), as calculated from the plasma data, and 121% as calculated from the urine data, respectively. The present results show that no statistically significant differences between the preparations exist for the relevant pharmacokinetic parameters (AUC-1, AUC-3, Cmax, tmax, Ae).This publication has 7 references indexed in Scilit:
- Plasma colchicine concentration in patients with recurrent polyserositis (familial mediterranean fever) on long‐term prophylaxisArthritis & Rheumatism, 1982
- A sensitive radioimmunoassay for colchicineJournal of Pharmacy and Pharmacology, 1980
- Colchicine kinetics in patients with familial Mediterranean feverClinical Pharmacology & Therapeutics, 1980
- Radioimmunoassay for Colchicine in Plasma and UrineScience, 1976
- Biliary excretion of colchicine.1975
- Colchicine, vinblastine and griseofulvin: Pharmacological studies with human leukocytesBiochemical Pharmacology, 1971